33
No.
Message
Meaning
Action
62
cannot bind to NETLINK socket
<error cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
Restart mcemonitor
automatically by cron.
63
cannot set FD_CLOEXEC flag on
fd <error cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
Restart mcemonitor
automatically by cron.
64
poll table overflow
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
Restart mcemonitor
automatically by cron.
65
cannot set FD_CLOEXEC flag on
fd
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
Restart mcemonitor
automatically by cron.
66
poll table overflow
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
Restart mcemonitor
automatically by cron.
67
poll error <error cause>
mcemonitor found a continuable
error. mcemonitor will continue to
be run safely.
An error occurred on
system-related function, but
mcemonitor continue operation.
mcemonitor continues
running. No action is needed.
68
Offlining CPU xx due to corrected
error threshold
Offline CPU xx due to corrected
error exceeds threshold.
–
69
Not offlining CPU 0 because of
kernel running on CPU 0.
Cannot offline CPU 0 because its
kernel is running.
–
70
Offlining CPU xx succeeded
Offlining CPU xx succeeded.
–
71
Offlining CPU xx failed
Offlineing CPU xx failed because
it was in use.
–
72
Kernel does not support page
offline interface
Kernel does not support
MemoryPage Offline.
–
73
Corrected memory errors on page
xx exceeded threshold
Correctable memory error on
page xx exceeded threshold
value.
–
74
Offlining page xx due to corrected
error threshold
Memory error on address xx
exceeded threshold value.
Offline memory page.
–
75
Not offlining page xx because this
offlining page has already
succeeded.
Do not offline memory page
because memory address xx has
already been offlined.
–
76
Not offlining page xx because this
offlining page has already failed.
Do not offline memory page
because memory address xx has
already been offlined.
–
77
Soft offlining of page xx
succeeded.
Memory Page Offline was
executed on address xx in Soft
Mode.
–
78
Soft offlining of page xx failed.
Could not offline the memory
page because the page was in
use.
Could not offline the memory
page because the page was
in use. Use syslog to confirm
attribute of page.
79
mcemonitor already running
mcemonitor is already running.
–