4-74 Configuring Your Server
As an example, define a RAID5 VD of yyyyy MB.
1.
Specify the necessary parameters in left columns.
2.
Enter "yyyyy" in "Select Size" field.
3.
Click [Accept] at the lower center of the screen.
4.
If you want to define another VD, click [Back] and repeat steps starting from Span
Definition screen.
5.
Upon completion of VD definition, click [Next].
IMPORTANT:
The value shown in "Select Size" indicates the maximum size
allowed for RAID1 or RAID6. You need to specify the maximum
size for RAID0 or RAID5 according to "Next LD, Possible RAID
Levels".
To use RAID 5 or RAID 6 with Internal RAID Controller
(equivalent to N8103-116), you need to additionally install the
optional N8103-119 RAID Upgrade Kit.
If N8103-119 RAID Upgrade Kit is not installed, do not select
"RAID5" that may appear in [RAID Level] box. If selected, you
will fail to save the configuration information. In such a case, you
need to define a VD again from the beginning.