Express5800/120Ed Rack Mount installation Procedures 13
Removing a Foot Stand
Each of the four foot stands located on the bottom of the server unit consists of a
three piece assembly and are easily removed (see Figure 10).
Note:
Each foot stand is secured with two small screws.
1.
Power off the system and remove the left side panel of the server unit as
described earlier in this chapter.
2.
Position the server unit on its right side.
3.
Remove the two screws securing the foot stand to the bottom of the server
unit. The two screws are located inside on the bottom of the server unit.
Note:
If an option card is installed in the bottom
expansion slot of the server unit, it may be necessary to
remove the option card, before the hex screw can be
removed that is located under the card.
4.
Remove the foot stand (stationary base, movable stand, and long stem nut)
from the server unit.
5.
Repeat steps 3 and 4 until all four foot stands are removed.