44
NEC D3-10i Quick Start Guide
44
Verifying Windows iSCSI Connectivity
After confirming that the array and application server are connected from the Storage Manager client, the next
step is to confirm that any logical disks that were created during the initialization process are available to the
application server.
1. From the application server, log on to the server with an account that has administrative privileges.
2. From the Start Menu, open the Computer
Management MMC by clicking
Administrative
Tools
and then
Computer Management
, or by
right-clicking
Computer
and then clicking
Manage
.
3. At the Computer Management window, select
Device Manager
, and then click
Disk Drives
on
the right to ensure that any logical disks are
visible from the application server.
4. In the Computer Management window, select
Disk Management
. If the logical drives that
were bound to this application server were not
initialized, a Windows Disk Initialization prompt
will appear.
If the Initialize Disk prompt does appear, select
the disks to initialize, choose the partition style to
be used for the new logical drives, and then click
OK
.