background image

English-2

Registration Information

FCC Information

1. 

Use the attached specified cables with this color monitor so as not to interfere with radio and  television reception.

 

(1) 

The power supply cord you use must have been approved by and comply with the safety standards of U.S.A.,  

 

 

and meet the following condition. 

Power supply cord 
Plug shape

Non shield type, 3-conductor

U.S.A

 

(2) 

Please use the supplied shielded video signal cable.   

 

 

 

 

 

 

  

 

Use of other cables and adapters may cause interference with radio and television reception.

2.  

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of 
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used 
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures:

 

•  

Reorient or relocate the receiving antenna. 

 

• 

Increase the separation between the equipment and receiver. 

 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

 

• 

Consult your dealer or an experienced radio/TV technician for help.

If necessary, the user should contact the dealer or an experienced radio/television technician for additional suggestions. The 
user may find the following booklet, prepared by the Federal Communications Commission, helpful: “How to Identify and 
Resolve Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington, 
D.C., 20402, Stock No. 004-000-00345-4.

Declaration of Conformity

This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions. (1) This device may not 
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 
undesired operation.

 

 

 

 

U.S. Responsible Party:  NEC Display Solutions of America, Inc.

 

 

 

 

Address: 

 

500 Park Blvd, Suite 1100 

 

 

 

 

 

 

 

Itasca, Illinois 60143 

 

 

 

 

Tel. No.:  

 

(630) 467-3000

 

 

 

 

Type of Product:   

Display Monitor

 

 

 

 

Equipment Classification:  Class B Peripheral

 

 

 

 

Models:   

 

AccuSync AS172 (L175GZ) 

 

 

 

 

 

 

 

AccuSync AS193i (L195GY)

     We hereby declare that the equipment specified above conforms 

to the technical standards as specified in the FCC Rules.

To see a list of our TCO certified monitors and their TCO Certification (in English only), visit our website at  

http://www.nec-display.com/global/about/legal_regulation/TCO_mn/index.html.

Summary of Contents for AccuSync AS172-BK

Page 1: ...Desktop Monitor AccuSync AS172 AccuSync AS193i User s Manual Please find your model name in the label on the backside of monitor...

Page 2: ...ions and Maintenance English 3 Ergonomics English 4 Cleaning the LCD Panel English 4 Cleaning the Cabinet English 4 Contents English 5 Quick Start English 5 Controls English 8 Specifications English 1...

Page 3: ...splay in accordance with the table below If a power cord is not supplied with this equipment please contact your supplier For all other cases please use a power cord that matches the AC voltage of the...

Page 4: ...relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Cons...

Page 5: ...lug your monitor from the wall outlet and move to a safe location then refer servicing to qualified service personnel under the following conditions If the monitor is used in this condition the monito...

Page 6: ...onomics To realize the maximum ergonomics benefits we recommend the following To avoid eye fatigue adjust the brightness to a moderate setting Place a sheet of white paper next to the LCD screen for l...

Page 7: ...To attach the AccuSync LCD monitor to your system follow these instructions NOTE Make sure to read Recommended Use page 3 before installation The accessories included will depend on the where the LCD...

Page 8: ...this User s Manual for a full description of these OSD controls NOTE If you have any problem please refer to the Troubleshooting section of this User s Manual Tilt Grasp both sides of the monitor scre...

Page 9: ...monitor must be mounted to an arm which guaranties the necessary stability under consideration of the weight of the monitor The LCD monitor shall only be used with an approved arm e g GS mark NOTE To...

Page 10: ...Icon select Displays OSD menu and selects function icon Moves leftward Moves rightward Displaying on screen Function adjustment Adjusts the function of the selected icon Adjusts down Adjusts up Reset...

Page 11: ...etting LEFT RIGHT Analog input only Controls Horizontal Image Position within the display area of the LCD DOWN UP Analog input only Controls Vertical Image Position within the display area of the LCD...

Page 12: ...DEO INPUT MENU after change Input Port DDC CI Turns ON or OFF the two way communication and control of the monitor CARBON SAVINGS Display the estimated carbon saving information in kg The carbon footp...

Page 13: ...all modes listed 1280 x 960 1 at 60 Hz to 75 Hz 1280 x 1024 at 60 Hz to 75 Hz Recommended resolution is 60 Hz for optimal display performance Active Display Area Horizontal 337 9 mm Vertical 270 3 mm...

Page 14: ...80 x 960 1 at 60 Hz to 75 Hz 1280 x 1024 at 60 Hz to 75 Hz Recommended resolution is 60 Hz for optimal display performance Active Display Area Horizontal 374 8 mm Vertical 299 8 mm Power Supply 100 24...

Page 15: ...rd s scanning frequency thus displaying the resolution required FullScan Capability Allows you to use the entire screen area in most resolutions significantly expanding image size VESA Standard Mounti...

Page 16: ...r shows rough images only Image is displayed only roughly pixels are missing and OSD warning OUT OF RANGE is displayed Either signal clock or resolution is too high Choose one of the supported modes O...

Page 17: ...r http www necdisplay com in USA Energy Saving This monitor features an advanced energy saving capability When a VESA Display Power Management Signalling DPMS Standard signal is sent to the monitor th...