background image

1C 

TABLE OF CONTENTS 

1. Safety Instructions ...........................................................................................................2 

2. Technical Specifications ...................................................................................................3 

3. How To Set The Unit ........................................................................................................4 

3.1 Control panel ............................................................................................................4 

3.2 Main Function...........................................................................................................5 

3.3 Home Position Adjust .............................................................................................13 

4. Control By Universal DMX Controller.............................................................................14 

4.1 DMX 512 Connection .............................................................................................14 

4.2 Address Setting ......................................................................................................15 

4.3 DMX 512 Configuration ..........................................................................................16 

5. Troubleshooting .............................................................................................................18 

6. Fixture Cleaning.............................................................................................................18 

Summary of Contents for WASH-500ZOOM

Page 1: ...WASH 500ZOOM User Manual Professional Entertainment Technology Professional LED Moving Head Washer Please read these instructions carefully before use with Motor Zoom Function ...

Page 2: ......

Page 3: ...ications 3 3 How To Set The Unit 4 3 1 Control panel 4 3 2 Main Function 5 3 3 Home Position Adjust 13 4 Control By Universal DMX Controller 14 4 1 DMX 512 Connection 14 4 2 Address Setting 15 4 3 DMX 512 Configuration 16 5 Troubleshooting 18 6 Fixture Cleaning 18 ...

Page 4: ...terials close to the unit while operating as it is fire hazard y Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base y Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this y Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power ...

Page 5: ...ttaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications Extr emely small fast an...

Page 6: ...et The Unit 3 1 Control panel Display To show the various menus and the selected functions LED POWER ON Power On NULL No function NULL No function DMX ON DMX input present Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions ...

Page 7: ...Main Function To select any of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the M...

Page 8: ...6C ...

Page 9: ...utton to view other DMX value Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Setting Enter MENU mode select Fixture Setting press ENTER button to confirm then use UP and DOWN button to select Pan Inverse Tile Inverse P T Feedback BL O P T Moving White Balance Cooling Mode or Dimmer Curve Pan Inverse Select Pan Inverse press ENTER button to confirm...

Page 10: ...lect No normal while pan tilt moving or Yes blackout while pan tilt moving press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode White Balance Select White Balance press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select Red Green or Blue Once selected press ENTER button then use UP and DOW...

Page 11: ... Law Light intensity control is coarser at low levels and finger at high levels S cure Light intensity control is finger at low levels and high levels and coarser at medium levels Display Setting Enter MENU mode select Display Setting press ENTER button to confirm use UP and DOWN button to select Display Inverse Backlight Auto Off Backlight Intensity Temperature unit Display Warning or Language Di...

Page 12: ...e minute to exit menu mode Temperature Unit Select Temperature Unit press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select or press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Display Warning Select Display Warning press ENTER button to confirm present mode will blink on the display u...

Page 13: ... button to confirm then use UP and DOWN button to adjust the value press ENTER button to store the fixture will run as the channel value indicates Press MENU button back to the last menu or exit menu mode let the unit idle one minute All channels value will become 0 after exiting Manual Test menu Fixture Information Enter MENU mode select Fixture Information press ENTER button to confirm use UP an...

Page 14: ... tilt to their home positions or No press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Zoom Reset Zoom Select Zoom press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset Zoom to their home positions or No press ENTER button to store Press MENU button to exit All Reset All Sele...

Page 15: ...xit Factory Setting Select Factory Setting press ENTER button to confirm the fixture will reset to factory settings and exit menu mode 3 3 Home Position Adjust In the main functions hold Enter button for at least 3 seconds into offset mode use DOWN and UP button up to chose Pan Offset Tilt Offset or Zoom Offset pressing ENTER button and the display will blink Use DOWN and UP button to adjust the h...

Page 16: ...ether in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the ...

Page 17: ... that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press ENTER button to confirm use UP and DOWN button to select DMX Address press ENTER button to confirm the present address will blink on the display use UP and DOWN button to adjust the address from 0 to 512 press ENTER button to store Press MENU button back to the last menu or let the unit idle 7 se...

Page 18: ...16C 4 3 DMX 512 Configuration 14 channel mode ...

Page 19: ...17C ...

Page 20: ...es run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 6 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried...

Reviews: