neat
22
NE41 11014-02 v4.1
WALL - Technical Handbook
4.6 Autoready
If the user forgets to press Ready when unit is in Presence or Assistance mode, the
unit automatically returns to Standby mode after 30 minutes (configurable to 1-255
minutes or Off) and an Autoready alarm is also sent.
4.7 Built in action plan
A built in action plan is stored in the memory and executed if the is unit set to
Radio Control Mode = No, function off, see "5.13.1 Radio parameters".
Button
Standby/Alarm mode
Presence/Assistance mode
1 (Red)
Send User Alarm.
Relay 1 is closed.
Relay 2 is opened.
Go to Alarm mode.
Send Assistance alarm.
Relay 1 is closed.
Relay 2 is closed.
Go to Assistance mode.
2 (Yellow)
Send Presence indication.
Relay 1 is opened.
Relay 2 is closed.
Go to Presence mode.
2 (Yellow)
2
Send Service alarm.
3 (Green)
Send Ready indication.
Relay 1 is opened.
Relay 2 is opened.
Go to Standby mode.
3 (Green)
2
Send Presence indication.
Relay 1 is opened.
Relay 2 is closed.
Go to Presence mode.
Send Ready indication.
Relay 1 is opened.
Relay 2 is opened.
Go to Standby mode.
IN1/Port 1
Send No alarm type alarm.
Relay 1 is closed.
Relay 2 is opened.
Go to Alarm mode.
Send Assistance alarm.
Relay 1 is closed.
Relay 2 is closed.
Go to Assistance mode.
IN2
Send Pull cord alarm.
Relay 1 is closed.
Relay 2 is opened.
Go to Alarm mode.
Send Assistance alarm.
Relay 1 is closed.
Relay 2 is closed.
Go to Assistance mode.
Port 2
Send User defined alarm.
Relay 1 is closed.
Relay 2 is opened.
Go to Alarm mode.
Send Assistance alarm.
Relay 1 is closed.
Relay 2 is closed.
Go to Assistance mode.
2
One button presence mode
Table 8.
Button actions for the built in action plan.