background image

8

TREX2G User manual NE41 11005-02 v1.4

Activate the transmitter. When a 

transmitter is received, the 

TREX2G  

displays the 

Add transmitter

 screen

.

Select identification

Select 

Room

 from the drop-down list 

and confirm

.

Scroll down to the four digit field just 

below and enter the number 

1

 in the 

rightmost position

.

Select equipment

Select 

Trigger

 from the equipment 

dropdown list

.

Summary of Contents for TREX2G

Page 1: ...Portable receiver User manual TREX2G neat NE41 11005 02 v1 4 ...

Page 2: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and recei...

Page 3: ...nce alarm 13 Misc settings 13 Other settings 13 Advanced settings 13 TREX 2G Technical handbook 14 TREX 2G Programmer 14 Troubleshooting 14 Important 15 Safety Notes 15 Use 15 Cleaning 15 Disposal 15 Technical data 16 Recommended AC adaptors 16 In the package 1 x TREX2G unit 1 x AC adaptor 230V 1 x USB Mini adaptor 1 x This user manual Depending on market different AC adaptors are sold please see ...

Page 4: ...ith the MiniUSB Adaptor included or the Charging Cradle optional MiniUSB adaptor included Connect the AC adap tor to the TREX2G with the MiniUSB adaptor Snap the Mini USB adaptor to the bottom of the unit from keyboardside down all the way until it snaps on its place on the back cover CHARGE charging stand optional Connect the unit s USB cable to CHARGE and either the accompanying AC Adaptor or a ...

Page 5: ...s B1 for 3 seconds remove USB cable before power off General functions Navigate up and down in the menus by pressing B1 and B2 The present value is highlighted in blue Confirm enter select a value setting by pressing B3 Return to the home screen by selecting Quit from the main menu Selecting Back in a menu returns to the previous menu Selecting Back and pressing holding B3 returns directly to the ...

Page 6: ... on Vibration enabled New alarm RFID enabled USB connected Battery charging battery status Enter the menus Enter the menus by pressing B2 Set time and date Set the date and time in the Main menu Preferences Date and time Select hours and minutes by pressing B1 and B2 confirm by pressing B3 Repeat for the date ...

Page 7: ...v1 4 After confirming date time the current date time is displayed Transmitters Adding a transmitter Example adding an ATOM used in Room 1 Go to Programming Add transmit ter A popup window appears asking for activation of the transmitter ...

Page 8: ... received the TREX2G displays the Add transmitter screen Select identification Select Room from the drop down list and confirm Scroll down to the four digit field just below and enter the number 1 in the rightmost position Select equipment Select Trigger from the equipment dropdown list ...

Page 9: ...NE41 11005 02 v1 4 Confirm selection by pressing B3 Select Save to confirm the transmit ter settings or Cancel to discard Saving is confirmed The transmitter is saved Erase a transmitter Go to Programming Erase trans mitter ...

Page 10: ...S D ATOM Positioning system Technical Handbook NE41 08001 02 Receiving alarms Activate an added transmitter TREX 2G beeps and a popup window appears displaying the alarm The lettersymbol in the topbar indicates that this is a new alarm and the 1 1 in the bottom indicates this is the first alarm of a total of 1 new alarms The data displayed is The transmitter Room and number 1 The equipment Trigger...

Page 11: ...he alarms are sorted as newest alarms first The alarm is displayed except for the letter symbol and now the bottom indicates 0 0 i e no new alarms Press B1 B2 or B3 to return to the Alarm list It is not possible to delete alarms from the alarmlist Multiple alarms Normal mode If two or more alarms are received at the same time the displays shows how many new alarms is received ...

Page 12: ...alarm in the list indicated by 1 2 To acknowledge the alarms in con secutive order keep pressing B3 Alarm list browsing However if the user wishes NOT to acknowledge the first oldest alarm in the list browse the alarms in the popup list and press B3 to acknowl edge the alarm desired The popup list will remain on screen until the user or someone else acknowledges the alarm s It is not possible to n...

Page 13: ...disable vibration in Main menu Preferences Vibration Backlight Enable or disable the automatic back light function and set the correspond ing timeout parameters in Main menu Preferences Back light Selecting backlight always on signifi cantly reduces battery operating time Tech info Displays technical information about the TREX2G Advanced settings The settings below are further ex plained in TREX 2...

Page 14: ...2G Programmer TREX 2G Programmer TREX2G is a a powerful tool to configure and customize the TREX2G All parameters and values in the TREX2G can be programmed with this software The software can be downloaded from our homepage Contact your distributor for more information Troubleshooting Q The TREX2G does not start A Is the battery fully charged A Is the TREX2G connected via USB to a computer If yes...

Page 15: ...ries if the unit is to be out of use or stored for an extended period of time Use Use only original parts Keep away from dust moist and dirt Do not drop knock twist or shake the device Do not warm up the device or use it near fire For repairs contact a NEAT dealer Cleaning All parts in the product kit can be cleaned with a mild soap solution and a damp cloth Dry with a dry cloth Strong chemicals a...

Page 16: ...x 60g including battery Temp range 5 55oC Battery type Li Po 600 mAh RF Frequency market depending EU 868 7 MHz 869 2 MHz Social alarms Category I 869 4 MHz US 916 MHz Recommended AC adaptors AC Adaptors market depending EU NE31 07006 13 5VDC 1A UK NE31 07006 09 5VDC 500 mA US NE31 15006 01 5VDC 1A ...