NE41 17030-02 v1.0
D-POS II
- Technical Handbook
neat
19
6.3.2 Radio transmitter
This section determines values for radio transmission.
Unit ID code
The Unit ID code is used as the Radio ID code for radio receivers.
Max number of short transmissions
Enter the max number of short transmissions. Default = 3.
Max number of long transmissions
Enter the max number of long transmissions. Default = 3.
Max number of bursts
Enter the max number of bursts. Default = 1.
Time between bursts (s)
Enter the desired time between burts. Default = 3
Ignore received acknowledge
Determine whether the D-POS II unit should ignore received acknowledge from other
radio transmitters. Default = No, function off (i.e. acknowledge is NOT ignored).
Radio test alarm interval (minutes)(0=off)
Set the interval for radio test alarms. Default = 0 (zero)
Transmit frequency band
Select which frequency band the unit should send in. Default = 869.2 MHz.
6.3.3 Alarm types
This section determines what alarm type to be sent when certain events occur. E.g. in
this example when the tamper switch is activated the D-POS II units sends a Tamper
alarm.
The default alarm types for events are:
Event
Alarm type
Button
No alarm type
Tamper
Tamper alarm
Antenna failure
Technical failure
EXT input
Door alarm
Radio test
Radio test alarm
Table 8.
Default alarm types
6.3.4 Plug-n-play
This is the equipment type. Default = 24.