Signal Strength and OSD Diagnostic Messages

When a receiver is connected to a monitor, self-explanatory diagnostic messages are displayed in the lower
left corner of the screen to inform the user of the receiver’s current status.

The messages will be displayed for 15 seconds, with the exception of 

Search for transmitter wireless signal

failed 

and 

No wireless signal detected: ss=0 vm=NONE

.

Search for transmitter wireless signal failed

 and 

No wireless signal detected: ss=0 vm=NONE

 will be dis-

played until remedial action is taken.

When the 

No wireless signal detected: ss=0 vm=NONE

 message and/or the 1-bar graph are displayed on the

screen, the wireless link is unreliable and 

requires immediate remedial action

.

The 

Signal Strength bar graph

 is displayed in the lower right corner of the receiver’s monitor for 60 seconds

at power up. It is also displayed when the link is established following a link disconnect.

When the link quality is poor or bad the bar graph is automatically displayed to alert the user that 

remedial

action is required

.

The 

OSD messages

 are displayed below the signal-strength bar.

(1)

(1)

Signal-strength bar

OSD Messages

No wireless signal detected: ss=0 vm=NONE

No DVI/SDI signal detected

Receiving wireless signal

Trying to establish wireless link

Unable to establish wireless link

Searching for transmitter wireless signal

Search for transmitter wireless signal failed

Signal-strength bar graphs

Excellent link quality

Acceptable link quality

Bad link quality or link down, frequent pixilation and/
or screen “freeze”

Summary of Contents for ZEROWIRE G2

Page 1: ...ZEROWIRE G2 Advanced Wireless HD Video Transmission System USER MANUAL ENGLISH ...

Page 2: ...e without notice NDS provides this informa tion as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be re produced by any mechanical electronic or other means in any form without prior written permission of NDS All trademarks are the property of t...

Page 3: ...ufacturer Date of manufacture YYYY MM DD Catalogue number Serial number Batch code Atmospheric pressure limitation Humidity limitation Temperature limit Waste management Fragile Keep dry This way up The Canadian Standards Association CSA certi fication mark represents safety approval by Cana dian Standards Associ ation for Canada and the United States EurAsian Conformity EAC mark represents safety...

Page 4: ...ains restricted sub stances The symbol number refers in years to the Environmental Protection Use Period EPUP during which the product can be safely used and following which should be imme diately recycled Equipotentiality Closed On Switch Open Off Switch Protective earth pro tective ground Alternating current Non ionizing electro magnetic radiation Symbols ...

Page 5: ... Co Channel Interference 26 4 12 Channel Usage 26 4 13 Multi System Installation 26 4 14 Signal Strength and OSD Diagnostic Messages 27 5 ZEROWIRE G2 Troubleshooting 28 6 Specifications 30 6 1 ZEROWIRE G2 Specifications 30 6 2 Maximum EIPR Output Power of Test Frequency 31 6 3 Supported Video Modes 31 6 4 ZEROWIRE G2 Accessory Kits by Display 32 6 5 Cleaning and Disinfecting Instructions 33 7 Elec...

Page 6: ......

Page 7: ... to modify the appearance graphics and technical data of the product through continued development of its products Please note Paragraphs marked with the words WARNING CAUTION and NOTE carry special meanings Sec tions marked with these words must be given special attention WARNING The safety and or health of the patient user or a third party are at risk Comply with this warning to avoid injury to ...

Page 8: ...void damage to the equipment This symbol denotes the manufacturer This symbol denotes the manufacturer s European Community representative This symbol indicates the device is a Medical Device This product is intended only for use by healthcare professionals in professional healthcare environments This product is T U V approved with respect to electric shock fire and mechanical hazards only in acco...

Page 9: ...declares that this ZEROWIRE G2 System is in compliance with the essen tial requirements and other relevant provisions of Directive 2014 53 EU The full text of the EU Declaration of Conformity is available upon request Federal USA law restricts this device to sale by or on the order of a physician Radio Approval This device meets the requirements of Draft EN302 567 V2 0 24 and conforms to Radio and...

Page 10: ...f the product The product and other medical equipment should be positioned so that the power cord and connection to AC mains is readily accessible If an extension cord or power strip is needed for connection of this product to AC mains confirm that the power cord plug can be securely connected to the cord or power strip This product should be powered from a center tapped circuit when used in the U...

Page 11: ...urgical procedures The ZEROWIRE G2 wireless video system is a non sterile reusable device not intended for use in the sterile field Contraindications 1 These units are non sterile reusable devices and are not intended for use within a sterile field 2 This equipment may not be used in the presence of flammable anesthetics mixture with air oxygen or ni trous oxide Do not use in MR Environments WARNI...

Page 12: ... s DVI input The units are powered from an NDS 24 VDC power supply or through the Y adapter cable NOTE The Y adapter cables are only for use with NDS displays that are powered by an NDS 24 VDC power supply For information on the Y adapter see Power Options 17 For a typical setup see Typical Installation 21 3 4 Noninterference Distance The listed devices on the following table have been tested to d...

Page 13: ...nd Receiver connector panels 1 ZEROWIRE G2 Transmitter 5 DVI input 2 ZEROWIRE G2 Receiver 6 DVI output 3 ON OFF switch 7 3G SDI input 4 Power connector 8 USB ports for firmware updates NOTE USB ports are used for installing updates to the Transmitter or Receiver firmware and not for use as a general purpose I O port ...

Page 14: ...Link LED 2 Link button 3 Status LED Transmitter 4 Status LED Receiver The LINK button is used to link a Transmitter to a Receiver On the Receiver the LINK button is also used to activate the Signal Strength bar graph described in section Signal Strength and OSD Diagnostic Messages 27 ...

Page 15: ...ng screws 15 Tighten the provided left side screws only 2 3 turns Remove the two right side screws from the VESA mount See B in graphic Installation back view mounting screws 15 A B Installation back view mounting screws With the mounting blade facing the front of the display slide the step bracket between the VESA mount and the back of the display until notches labeled for the display you are wor...

Page 16: ...of the ZEROWIRE G2 Transmitter or Receiver module facing the front of the display align the slot on the bottom of the module with the mounting blade and push the module onto the mounting blade until the module is firmly seated See D in graphic Installation back view step bracket and modules 16 ...

Page 17: ...ry kit see ZEROWIRE G2 Accessory Kits by Display 32 to determine the correct accessory kit for the NDS display being used ZEROWIRE G2 Transmitter and Receiver units can also be powered using the included 24 VDC power supply SwitchCraft Y Adapter Cable 35X0096 XLR Y Adapter Cable 35X0097 1 2 1 Model numbers of 24 VDC power supplies 2 J3 of the Y adapter or 24 VDC power supply cable connects here Gl...

Page 18: ... and Installation 4 4 Wiring Diagrams ZEROWIRE G2 Transmitter Wiring 1 2 3 4 5 1 DVI video source 2 DVI output DVI cable 3 SDI output optional 3G SDI cable 4 Power to display 24 VDC 5 Power to transmitter 24 VDC ...

Page 19: ...able whichever is greater Sharper bends may damage the cable and or degrade the video signal 4 6 Setup Linking the Transmitter and Receiver Prior to placing the ZEROWIRE G2 system in service the Transmitter and Receiver pair must be linked Once a Transmitter and Receiver pair is linked they remain linked until the Transmitter is explicitly linked to another Receiver or the Receiver is explicitly l...

Page 20: ...3 Press and hold the LINK button 6 on the Transmitter 2 unit until its linking LED 5 begins flashing blue rapidly then release 4 When the Transmitter and Receiver units identify each other and begin to link both the status LED 7 8 and link LED 5 on both units will flash rapidly for several seconds Once the link is established each unit s linking LED turns off 5 6 2 7 3 8 1 2 3 4 Linking procedure ...

Page 21: ...e of sight operation i e the pair will op erate reliably despite the presence of intervening obstacles However neither unit should be completely surrounded by metallic objects 4 7 Typical Installation WARNING For mission critical applications we strongly recommend that a replacement ZEROWIRE G2 transmitter and receiver pair and a DVI cable be immediately available Additionally we recommend that a ...

Page 22: ...nes in section Positioning and Orientation 22 4 The transmitter and receiver should be facing each other and be visible to each other in free air space 5 For non line of sight applications we recommend that the Transmitter and Receiver be located within 6 feet 1 8 m or less from the walls 4 9 Positioning and Orientation Due to the shape of the antenna s signal field both Transmitter and Receiver u...

Page 23: ...ransmitter 2 Field shape Elevation The Transmitter and Receiver should be positioned at least 5 feet 1 5 m above the floor be at the same height and preferably with the Transmitter and Receiver front edges parallel and facing each other ...

Page 24: ...itter and Receiver of up to 30 feet 9 1 m However in the case of most OR environments best results are achieved with a horizontal dis tance of up to 8 feet 2 4 m Min 5 ft 1 5 m Max 8 ft 2 4 m Min 5 ft 1 5 m 1 2 3 4 5 6 7 1 ZEROWIRE G2 Transmitter 5 Roll stand 2 Primary display 6 Surgical table 3 Secondary display 7 Endoscopy cart 4 ZEROWIRE G2 Receiver ...

Page 25: ...Transmitter and Receiver see illustration below Preferably surgical lights should be positioned out of the way or raised above the line of sight If an object must obstruct the line of sight the best option is to position it half way between the Transmitter and the Re ceiver OR rooms whose walls and or ceiling are constructed with metal sheets may reduce ZEROWIRE G2 perform ance This condition poss...

Page 26: ... The recommendations listed below should be used to determine the appropriate setting 1 ZEROWIRE G2 Transmitter and or Receiver units cannot be used with earlier ZEROWIRE G2 Transmit ter and or Receiver units 2 A maximum of two ZEROWIRE G2 systems may be operated in the same room The transmitters and re ceivers should be separated by at least 3 feet 1 m within the room 3 Groups of two ZEROWIRE G2 ...

Page 27: ...s link is unreliable and requires immediate remedial action The Signal Strength bar graph is displayed in the lower right corner of the receiver s monitor for 60 seconds at power up It is also displayed when the link is established following a link disconnect When the link quality is poor or bad the bar graph is automatically displayed to alert the user that remedial action is required The OSD mes...

Page 28: ...Transmitter s and Receiver s power not the display Fails to establish link after attempting to pair The Transmitter and the Receiver units cannot ne gotiate the RF Channel to connect on Cycle both ZEROWIRE G2 Transmitter s and Re ceiver s power Poor or intermittent video Transmitter and Receiver are spaced more than 30 feet 9 1 m apart Reduce the spacing between the Transmitter and Re ceiver to 30...

Page 29: ...iption Blue and blinking slowly The unit is scanning for a channel Blue and flashing rapidly Unit is attempting to link Blue and steady The unit is sending Transmitter or receiving Re ceiver video data Blue alternating ON OFF for 3 seconds No Linking Information stored ...

Page 30: ...R 2 RF power out 28 dBm MHz EIRP Maximum range 30 ft 9 14 m Data rate 950 Mbps 3 8 Gb s Power consumption 8 W The effective range may vary depending upon the environment in which the product is operating Follow the instructions in section Setup 19 to achieve optimum performance and range Physical dimensions 9 3 in x 3 4 in x 2 0 in 236 mm x 87 mm x 52 mm Single Unit weight 1 0 lb 0 45 kg Operating...

Page 31: ... 562 1080i 25 1920 1080 2640 562 720p 60 1280 720 1650 750 720p 50 1280 720 1980 750 480p 60 720 480 870 525 576p 50 720 576 864 625 VGA 60 640 480 800 525 SVGA 60 800 600 1056 628 XGA 60 1024 768 1344 806 SXGA 60 1280 1024 1688 1066 UXGA 60 1600 1200 2160 1250 Custom mode 60 1280 1024 1688 1066 Custom mode 60 1292 960 1576 1000 Custom mode 60 1023 768 1396 806 Custom mode 60 1248 1024 1688 1066 C...

Page 32: ...MMI 26 standard 90R0029 90Z0152 90Z0153 With fiber 90R0030 Radiance G2 26 standard 90R0050 90Z0152 90Z0153 With fiber 90R0051 China model 90R0061 Radiance G2 HB 26 standard 90R0052 90Z0154 90Z0155 With fiber 90R0053 China model 90R0062 Radiance Ultra 27 standard 90R0104 90Z0156 90Z0157 With analog board 90R0102 With digital board 90R0100 Radiance G2 42 standard 90R0070 90Z0158 90Z0159 Radiance G2 ...

Page 33: ...h a lint free cloth that has been dampened with an acceptable clean ing agent Acceptable cleaning materials are listed below Remove residual detergent by wiping all exterior surfaces with a lint free cloth dampened with distilled water Disinfecting the device Disinfect the unit by wiping all exterior surfaces with a lint free cloth dampened with 80 Ethyl Alcohol Allow the unit to air dry Acceptabl...

Page 34: ...er might need to take mitigation measures such as relocating or re orienting the equipment The following EMC tables are provided for your reference 7 1 Guidance and Manufacturer s Declaration Electromagnetic Emissions The product is intended for use in an environment as described below The user operator of the product should make sure the device is operated within such an environment Emissions tes...

Page 35: ... 0 5 1 2 kV 0 5 1 kV Conducted RF IEC 61000 4 6 3 V 0 15 MHz 80 M Hz 6 V ISM Bands 80 AM 1 kHz Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m 50 or 60 Hz Voltage dips short interruptions and voltage vari ations on power supply input lines IEC 61000 4 11 100 dip 0 5 periods 0 45 90 135 180 225 270 315 100 dip 1 period 30 dip 25 30 periods 50 60 Hz Interrupt 100 drop 5 s NOTE Field str...

Page 36: ... devices can have an effect on the performance characteristics of the device Therefore such devices must be kept a minimum distance of 30 cm independ ent of any calculation from the insufflator its accessories and cables Rated maximum output power W of transmitter Separation distance in meters according to frequency of transmitter 150kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 7 GHz 0 01 0 12 0 1...

Page 37: ...o try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult your dealer or an experienced radio TV technician for help Accessory equipment connected to this product must ...

Page 38: ...BILITY FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT WITH RESPECT TO ALL NDS PRODUCTS OR SERVICES ANY AND ALL OTHER WARRANTIES REPRESENTATIONS AND OR GUARANTEES OF ANY TYPE NATURE OR EX TENT BE IT IMPLIED EXPRESS AND OR WHETHER ARISING UNDER OR AS A RESULT OF ANY STATUTE LAW COM MERCIAL USAGE CUSTOM TRADE OR OTHERWISE ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED NDS its suppliers and or distributo...

Page 39: ......

Page 40: ...H Werk 4 92442 Wackersdorf Germany Tel 49 9431 7984 0 info novanta europe novanta com Asia Pacific Novanta Japan East Square Omori 6 20 14 Minamioi Shinagawa ku Tokyo 140 0013 Japan 81 3 5753 2466 info ndssi com Oriental Media Center Suite 1510 Tower C No 4 Guang Hua Road Chao Yang District Beijing 100026 China 86 10 8559 7859 info ndssi com NDS Quality System ISO 13485 FDA Registration 2954921 ...

Reviews: