background image

 

2

INSTRUCTIONS FOR THE PROPER DISPOSAL

 

This  electronic  product  is  subject  to  the  European 
Directive 2012/19 / EU. Comply with local waste disposal 
regulations, do not dispose of old products with normal 
household waste. The proper disposal of products that 
can  no  longer  be  used  prevents  potential  negative 
consequences  for  the  environment  and  for  the 
population.

Summary of Contents for SUNCONTROL2

Page 1: ...1 SUNCONTROL2 User manual Valid for the following models SC320M SC350M...

Page 2: ...e European Directive 2012 19 EU Comply with local waste disposal regulations do not dispose of old products with normal household waste The proper disposal of products that can no longer be used preve...

Page 3: ...fety instructions 2 2 Package contents 3 3 DESCRIPTION 3 4 operations 5 5 installation 6 6 charging curve selection 8 7 Led indicators 10 8 Fuse replacement 11 9 Technical features 12 10 F A Q 14 11 w...

Page 4: ...ain To avoid risk of electric shock and or fire the vehicle s fuel system must be in good condition In case of damaged connecting cables or inadequate section immediately replace them with suitable ca...

Page 5: ...ce than the PWM technology up to 25 more SUNCONTROL2 available in two models SC320M and SC350M manages depending on the model up to 350W input with a maximum charge of 25A The new microprocessor equip...

Page 6: ...mple and fast way The touch screen display DT002 optional with new management software allows you to view the charge information and set the various settings with the new communication protocol NDS MA...

Page 7: ...ill be charged with the selected curve The Starting Battery will be charged if the following conditions are satisfied Leisure battery charged between 80 and 100 Starting battery with voltage under 12...

Page 8: ...use replacement On the front side after the power connections there s a Dip Switch for the charging curve selection it s important to select the correct curve according to the type of battery supplied...

Page 9: ...ay inadvertently discharge the leisure battery N PIN CONNECTION 1 Display Connection 2 Secondary connection for future connections 3 Solar Panel Negative poles 4 Batteries Negative poles 5 Solar Panel...

Page 10: ...esulphation ON 6 LiFePO4 Lithium Maintenance OFF 7 LiFePO4 Lithium Maintenance ON 1 OFF 2 OFF 3 OFF 1 OFF 2 OFF 3 ON 1 OFF 2 ON 3 OFF 1 OFF 2 ON 3 ON 1 ON 2 OFF 3 OFF 1 ON 2 OFF 3 ON 1 ON 2 ON 3 OFF 1...

Page 11: ...urve Vmax The delivered current will decrease as the battery state of charge increases till about 3A Timeout 6 hours DESULPHATION ONLY IF SELECTED An approximately 2A constant current will be delivere...

Page 12: ...ws an error due to the internal fuse breaking or services battery voltage below 6V B2 PHASE DISCUSSION PULSE CHARGE With voltage between 8V and 10 5V a variable current between 1A and 2A every 5 secon...

Page 13: ...plied or with a common 25A for SC320M or 30A for SC350M automotive fuse Follow these steps to reach the fuse 1 Remove SUNCONTROL2 from its housing 2 Rotate the device to reveal the screws on the botto...

Page 14: ...0W OUTPUT B1 Battery nominal voltage 12V 12V Charging current maximum output 20A 25A Minumum battery capacity required Lead acid 60Ah 80Ah Minumum battery capacity required LiFePO4 40Ah 50Ah Mimumum b...

Page 15: ...rithm OPTICHARGE Yes Yes Stand by self consumption 2mA 2mA Display connection Yes Yes Internal protection fuse 25A 30A Reverse polarity protection Yes Yes Night time discharge protection Yes Yes Overl...

Page 16: ...to connect just one bigger solar panel 200W for example on SUNCONTROL2 Pin N 5 but you must connect Pin N 5 and Pin N 6 Use at least a 6 mm2 cross size cable Is it normal to have a battery voltage wi...

Page 17: ...r ndsenergy it tel 39 085 4470396 fax 39 085 9112263 Seller s stamp and signature Warranty coupon model____________________________________________________________ Serial Number_______________________...

Page 18: ...16...

Page 19: ...17...

Page 20: ...serve all the energy you need 0037_MANB_Sc320_Sc350_GB02 NDS ENERGY s r l Via Pascoli 169 65010 Cappelle sul Tavo Pe Italy Tel 39 085 4470396 web www ndsenergy it email customer ndsenergy it LIKE US...

Reviews: