background image

ExpandOR™

 

Medical-Grade Video Streaming System  

USER MANUAL 

E N G L I S H 

Summary of Contents for ExpandOR

Page 1: ...ExpandOR Medical Grade Video Streaming System USER MANUAL ENGLISH ...

Page 2: ......

Page 3: ...without notice NDS provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDS All trademarks are the property of their...

Page 4: ......

Page 5: ...ifications 2 Section 3 ExpandOR Connections 3 Cable Bend Radius 3 Section 4 Transmit 4 Section 5 Receive 5 Section 6 Simultaneous Transmit Receive 6 Section 7 Transmitting to Multiple Locations 7 Audio Setup 7 Section 8 Privacy Feature 8 Record and Capture Features 9 Record Video Feature 9 Capture Still Feature 9 Section 9 Configuration Options 10 Cleaning Instructions 11 Electromagnetic Compatibi...

Page 6: ...No modifications are allowed This equipment system is intended for use by healthcare professionals only Safety Compliance This product is T U V approved with respect to electric shock fire and mechanical hazards only in accordance with CAN CSA C22 2 NO 60601 1 and ANSI AAMI ES60601 1 Safety Compliance This product meets the requirements of EN60601 1 so as to conform to the Medical Device Directive...

Page 7: ...s appropriate they reserve all patent copyright and other proprietary rights to this document including all design manufacturing reproduction use and sales rights thereto except to the extent said rights are expressly granted to others FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 93 42 EEC of the Council Directives of European Standards Direct...

Page 8: ......

Page 9: ...tup by the IT Department a doctor or a nurse in the operating room can easily Initiate streaming and or capturing session Enable privacy in compliance with security requirements such as HIPAA End streaming session NDS recommends that the installation and initial setup is done by the hospital s IT department by a technician with a basic understanding of networking including an understanding of TCP ...

Page 10: ...etworking including an understanding of TCP IP Protocol IP Address Gateway Subnet Mask Network Port Pinging a device on the same network configuring a laptop to work in a corporate hospital network For mission critical applications we strongly recommend that a replacement unit be immediately available Specifications are subject to change without notice Contact factory for current specifications DC...

Page 11: ...hone must be connected to the IN MIC connector and headphones or an amplified speaker must be connected to the OUT LINE connector Additionally Options 1 or 2 above must be implemented The diagram below shows the devices that may be connected to the ExpandOR The unit s application will determine which of these devices is required The devices required for a given function are described in the Connec...

Page 12: ...until the LED below it turns on Turn privacy off by pressing the PRIVACY button until the LED turns off See page 8 for more on PRIVACY 5 Pressing the CAPTURE STILL button as shown below captures a video frame as a still image saved to the USB drive The CAPTURE STILL LED flashes once during the capture See page 9 for more on the CAPTURE STILL function 6 Press the TRANSMIT button again to end transm...

Page 13: ... pressing the RECEIVE button as shown in Step 2 above The RECEIVE LED turns off If vid eo was being recorded ending receive also ends video recording and the RECORD VIDEO LED is turned off 3 If you want to record the video stream and or capture images verify with your IT department that the ExpandOR is setup for video streaming and or capturing images If it is then proceed as shown below Start rec...

Page 14: ... 2 above Stop receiving by pressing the RECEIVE button as shown in Step 3 The TRANSMIT LED and the RECEIVE LED turn off If video was be ing recorded ending receive also ends video recording turning off the RECORD VIDEO LED If you want to record the video stream and or capture images verify with your IT department that the ExpandOR is setup for video streaming and or capturing images If it is then ...

Page 15: ...tment can set it up if required When the ExpandOR has been configured for broadcasting press the TRANSMIT button shown below to begin broadcasting to destinations defined in the ExpandOR configuration 7 Audio Setup The ExpandOR can be configured to transmit and receive audio with its surgical video stream If your application requires audio your IT department can configure the ExpandOR to support a...

Page 16: ...he screen shown below and audio will be muted Privacy is enabled or disabled by pressing the PRIVACY button on the front panel When Privacy Mode is on the LED below the PRIVACY button will be on When the Privacy Mode is off the LED will be off Note HIPAA is the Health Insurance Portability and Accountability Act which sets the standard for protecting sensitive patient data 8 ...

Page 17: ... images are saved as a jpg files and are stored in the Image folder of the installed USB drive No additional action by the user is required Note The capture feature may be configured to capture frames from either the output video stream or Record Video Feature 1 A USB drive must be installed in the USB connector on the back of the ExpandOR before using this feature USB drives must be USB 2 0 or be...

Page 18: ...y the device with which it is communicating The table below each device shows direction parameters for device combinations From ExpandOR Signal Direction Transmit Yes Receive Yes Both Yes Signal Direction Transmit Yes Receive Yes Both Yes To ExpandOR Signal Direction Transmit Yes Receive No Both No Signal Direction Transmit No Receive Yes Both No From ExpandOR To PC ...

Page 19: ...lint free cloth dampened with 80 Ethyl Alcohol Allow the unit to air dry Cautions Do not allow liquids to enter the interior of the unit and do not permit exterior surfaces to come into contact will unacceptable solvents such as those listed below as severe damage to the unit may result Acceptable Cleaning Materials Vinegar distilled white vinegar 5 acidity Ammonia based glass cleaner Acceptable D...

Page 20: ...or to a surgical procedure The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals CISPR 11 class A If it is used in a residential environment for which CISPR 11 class B is normally required this equipment might not offer adequate protection to radio frequency communication services The user might need to take mitigation measures such as relocatin...

Page 21: ...are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The product is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC...

Page 22: ...se in the electromagnetic environment specified below The customer or the user of the product should assure that it is used in such an environment Immunity Test Immunity Test Electrostatic discharge ESD IEC 61000 4 2 2 4 6 8kV contract discharge 2 4 6 8 15 kV air discharge Radiated RF field IEC 61000 4 3 3 V m 80 MHz 2 7 GHz 80 AM 1 kHz Proximity fields from wireless transmitters IEC 61000 4 3 80M...

Page 23: ...t For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range ...

Page 24: ......

Page 25: ...ing Germany 49 89 31 707 100 info novanta europe novanta com Asia Pacific Novanta Japan East Square Omori 6 20 14 Minamioi Shinagawa ku Tokyo 140 0013 Japan 81 3 5753 2466 info ndssi com Oriental Media Center Suite 2302 Tower C No 4 Guang Hua Road Chao Yang District Beijing 100026 China 86 10 8559 7859 info ndssi com NDS Quality System ISO 13485 FDA Registration 2954921 ...