WARNINGS 

 

This  manual  is  dedicated  to  the  technical  personnel  responsible  of  the  installation, 
management and maintenance of the plants. The manufacturer assumes no responsibility for 
damages  or  malfunctions  occurring  after  intervention  by  non-authorized  personnel,  or  not 
compliant with the prescribed instructions. 

 
Before  performing  any maintenance  or  repair  action,  ensure  that the  system  is  electrically 
and hydraulically insulated. 
 

Dispose of waste material and consumables accordingly with local regulations. 

 

 

 
 
GENERAL SAFETY TIPS 

 
WARNING!

 Before performing any operation on the pump, unplug the pump and discharge 

the liquid from the pump head and tubes.

 Never operate on working pump! 

 
During  maintenance  and  repair  of  parts  that  normally  become  in  contact  with  chemicals, 

always wear all prescribed personal protections (gloves, clothes, glasses, etc.). 
The pump has to be handled by qualified personnel only. Always use original spare parts for 
maintenance. 

 

Failure  to  follow  instructions  can  cause  damage  to  the  equipment  and,  in  extreme  cases,  to 
people. 

 

 

 
How to ship the instrument 

To send back the device for repairing or calibration purposes, proceed as follows: 

  Fill the module “REPAIR REQUEST AND DECONTAMINATION DECLARATION” supplied with this 

manual, and include it in the transport documentation. 

  Clean the device properly, to eliminate any hazardous residuals. 

 

 

 

The manufacturer can modify the instrument or the technical manual without advanced notice. 

 

 

Warranty 

All our products are warranted for a period of 12 months from the delivery date.  
Warranty is not valid if all instructions of installation, maintenance and use, are not strictly followed by the user.  
Local regulations and applicable standards have also to be followed. 
In particular, the warranties regarding the operational safety and reliability of dosing pumps will be recognized 
only if the following conditions are fulfilled: 

o

  The installation, wiring, adjustment, maintenance and repairs performed only by qualified personnel 

o

  Only original spare parts have been used for repairs 

 

 

 

Summary of Contents for DDPHCL2

Page 1: ...DDPHCL2 Unit pH Chlorine Control INSTRUCTION MANUAL...

Page 2: ...Always use original spare parts for maintenance Failure to follow instructions can cause damage to the equipment and in extreme cases to people How to ship the instrument To send back the device for r...

Page 3: ...ONNECTIONS 9 Level Control 9 Flow Control 9 INTERNAL CONNECTIONS for technical personnel only 10 START UP 10 VISUALIZATIONS 11 OPERATION OF THE ELECTRONIC UNIT 11 Standard Configuration 11 Advanced Co...

Page 4: ...ow probe holder INSTALLATION Warning Always follow the warnings and general safety information referred at the beginning of this manual Install the DDPHCL2 unit away from heat sources in a dry place p...

Page 5: ...rs LCD with backlight Electrode holder down flow type transparent methacrylate body with standard connections for 8x12 tube and sampling needle Peristaltic Pumps Flow rate 1 5 l h 1 bar for pH adjustm...

Page 6: ...acid dosage Peristaltic pump 2 for chlorine dosage Transparent methacrylate down flow type electrode holder Bottom view connections POWER Prewired power cable LEV1 Level sensor connector for acid pum...

Page 7: ...r modifications Key Scrolls the available menus options in calibration and configuration modes decreases the displayed value Key Scrolls the available menus options in calibration and configuration mo...

Page 8: ...he pump head 6 Locate the PVC Crystal tube inside the tank and or the suction lance 7 Unscrew the fixing nut of the foot filter 8 Cut the transparent PVC Crystal tube 9 Insert the fixing nut and the t...

Page 9: ...el sensors one for each pump and flow sensor are available on special connectors that allow an extremely fast and easy connection even for unskilled personnel Note the pH and redox inputs should never...

Page 10: ...nections line neutral of the power supply does not affect the normal operation If the level and flow inputs are not used leave them open not connected START UP At start up the microcontroller displays...

Page 11: ...of fault or alarm condition the pump stops dosing until the normal working conditions are restored OPERATION OF THE ELECTRONIC UNIT To access the configuration calibration and manual mode menus press...

Page 12: ...eresis Pump 1 0 20pH 2 00pH 0 50pH P04 Dosage Pump 1 Acidification Alkalization Acidification P05 Time Base Pump 1 if P01 ON OFF if P01 Proportional 5 30 sec 100 360 sec 60 60 sec P06 Functioning Type...

Page 13: ...red for proportional operation this parameter indicates the time base of pump PARAMETER 06 FUNCTIONING TYPE OF THE PUMP 2 This parameter allows to set the functioning type of pump 2 typically used for...

Page 14: ...you need to send back the unit to the factory for a complete reconfiguration out of warranty PARAMETER 17 FUNCTIONING OF THE ALARM OUTPUT This feature is not used for this unit PARAMETER 18 FLOW FUNC...

Page 15: ...er solution contaminated or expired b electrode faulty or dead c connection cable or connector damaged If you try to calibrate the offset at a pH value too different from 7 00 the calibration is autom...

Page 16: ...y one pump at a time can be activated CONTROL EXAMPLES Typical application in swimming pool control acidification when pH exceeds the pH value of 7 30 Refer to the List of configuration parameters and...

Page 17: ...ns are not expired or contaminated repeat the procedure MAINTENANCE The periodic maintenance operations are essential for the proper functioning of the system and its duration in time The below advice...

Page 18: ...utting down the system for wintering or anyway for a long period dose clean water to rinse the tube then rotate the roller holder clockwise to position it as shown in the figure pH and Redox Electrode...

Page 19: ...d kit PVC Crystal suction hose 2 m PE delivery hose 2 m injection valve and foot filter 96000100 Spare blue front case for peristaltic pump with O ring 96000141 Transparent front cover for peristaltic...

Reviews: