![NCTE 7000 Series Instruction Manual And Data Sheet Download Page 11](http://html.mh-extra.com/html/ncte/7000-series/7000-series_instruction-manual-and-data-sheet_714935011.webp)
_______________________________________________________________________________________
_______________________________________________________________________________________
Page 11 of 20
5
EMV Emission data
EMV immunity and emitted interference (DIN EN IEC 61000-6-2 / DIN EN IEC 61000-6-4 / DIN EN 61326-1)
Examination
Test specification
Admission
Evaluation criteria
Discharge of static
electricity (ESD)
IEC 61000-4-2
± 6 kV Contact
discharge
A
passed
Electromagnetic HF-
field
IEC 61000-4-3
80 - 1000 MHz; 10 V/m;
80% AM
A
passed
Rapid transients
IEC 61000-4-4
± 2 kV
A
passed
High frequency,
asymmetrical
IEC 61000-4-6
0.15 - 80 MHz; 10V;
80% AM
A
passed
Examination
Test specification
Admission
Evaluation criteria
Interference voltage
0.15 - 30 MHz
CISPR 11:2009 +
A1:2010
Class B
Limit values observed
Radio interference field
strength
30 - 1000 MHz
CISPR 11:2009 +
A1:2010
Class B
Limit values observed
6
Wiring connected.
7
Based on the non-contact measurement principle the torque sensor is quite insensitive to bending and shearing forces. Self-aligning couplings are
recommended in case of dynamic loads.
Power supply
Unit
Value
15
Supply voltage
VDC
9 … 28
16
Current consumption (max.)
mA
100
17
Start-up peak
mA
< 100
18
Absolute max. supply voltage
VDC
30
General information
Unit
Value
19
Protection class according to
EN 60529
6
IP
50/65
20
Reference temperature
°C
+15 … +35
21
Operational temperature range
°C
-40 … +85
22
Storage temperature range
°C
-40 … +85
Nominal torque (bi-directional)
Nm
3000 / 5000
Customer-specific
23
Weight
kg
4.2
-
24
Moment of inertia
kg mm
2
7850
-
Load limits
7
Unit
Value
25
Maximum measurable torque
Nm
5000
8000