
567HUPLQDWRU%\WH
8VHUV*XLGH
RS-232 Terminator Byte
Controls the use of terminator bytes. If you use an
RS-232 Terminator Byte, it goes at the end of the message
sent to the host terminal or PC. If you included a BCC (RS-
232 Parameters -2 programming mode), it follows the
Terminator Byte and includes the Terminator Byte in the
calculation.
Contains two selections: Disable and Enable. Scan the Hex 0
tag to disable the Terminator Byte or scan the Hex 1 tag to
enable it. The default is Enable.
Specifies what ASCII code to use for the Terminator Byte.
Enter your selection by scanning the two appropriate Hex tags
as listed in the ASCII Code Chart in Appendix A. Although
you can select any value from 01 through 7F (Hex), the End
of Text (ETX) ASCII Code is recommended (Hex 03 or
Carriage Return, which is Hex 0D). If do not use Hex 03, 01 -
0F (Hex) are recommended. Scan the two appropriate Hex
tags (Hex 0 through Hex 7 for the first character and Hex 0
through Hex F for the second). The default is 0D.
Terminator Byte
ASCII Code
Summary of Contents for 7800
Page 1: ...NCR 7800 Consumer Price Verifier User s Guide BD20 1306 A Release C September 1997...
Page 16: ...DVHU 6DIHW LY 8VHU V XLGH...
Page 18: ......
Page 22: ......
Page 30: ......
Page 35: ...QVWDOODWLRQ 8VHU V XLGH 1 3 0 9 8 1 3 0 9 3...
Page 38: ......
Page 46: ......
Page 80: ...3DUDPHWHU 9HUVLRQ 1XPEHU 8VHU V XLGH...
Page 82: ......
Page 92: ......
Page 101: ...Index...
Page 102: ......