![NCE Mini Panel Manual Download Page 5](http://html2.mh-extra.com/html/nce/mini-panel/mini-panel_manual_3686828005.webp)
We want to setup the panel so press "1" to enter setup mode, this will present the
display screen as below
SETUP MINI PANEL
1=INPUT 2=CONFIG
Press "1" to setup an INPUT.
SETUP INPUT MENU
INPUT NUMBER: 01
We will start programming the inputs with input number 1. Type “1” followed by
“ENTER” to program input number 1
SETUP INPUT MENU
STEP NUMBER: 1
Normally when setting up an input we start with step number 1. We want to start
programming at step 1 so just press ENTER to accept that step. Commands will be
sent from the Mini Panel in order of their step number until an ‘empty’ step is
encountered or four steps are completed.
INP: 01 STEP: 1
1=ACCY 2=MACRO
At this point we’re ready to tell the mini panel exactly which command to send when
button 1 is pushed. Press “1” to send an accessory command.
INP: 01 STEP: 1
ACCY NUMBER:
Type the accessory number “1” followed by “ENTER”. Allowable NMRA accessory
addresses are 1-2044. Accessory number 2044 is the broadcast address for
accessories. There is no accessory address 0.
INP: 01 STEP: 1
1=NORM 2=REV
Press “1” to send the accessory command for Normal when button 1 is pressed.
INP: 01 STEP: 2
1=ACCY 2=MACRO
Note that the step number has increased to 2 indicating the last command has been
accepted and the Mini Panel is ready for the next command for this input. We don’t
need any more commands for this input so press “PROG/ESC” to return to the main
menu.
1=SETUP 2=REVIEW
3=TEST OPERATION
Let’s review the command that has just been programmed. Press “2” to review.
1=SETUP 2=REVIEW
REVIEW INPUT:
Type “1” and press “ENTER” to review the command sent by input number 1
INP: 01 STEP: 1
ACCY: 001 NORM
Last revised: 9 December 2008 Page 5