NCE Mini Panel Manual Download Page 1

Mini Panel

Accy and Macro Controller

 

Dimensions:  3.20" x 2.70"   (81 x 69 mm)

Revision 1.00 

$49.95

Build the kind of control panels you’ve always

wanted without complicated wiring!

Use one button to control multiple switches or macros on your NCE DCC

Up to 30 pushbuttons, toggle switches, block detectors, etc. can be

connected for control of turnouts, signals and other devices

Easy programming, just plug in a ProCab

Simple hook up, one Cab Bus connection and 2 wires for each

pushbutton or other input device

Can be used to perform simple automatic train control and other

layout automation tasks

05240230

05240230

This book, schematics and artwork copyright 2008 

NCE Corporation   82 East Main Street   Webster, NY  14580

            Last revised:  9 December 2008                                                                              

Summary of Contents for Mini Panel

Page 1: ...gle switches block detectors etc can be connected for control of turnouts signals and other devices Easy programming just plug in a ProCab Simple hook up one Cab Bus connection and 2 wires for each pu...

Page 2: ...activated by connecting them to the mini panel GROUND This makes the mini panel compatible with pushbutton toggle switches and most block detectors Virtually any device that provides a contact closur...

Page 3: ...Below is an example of a control panel for a simple yard with 3 tracks off the mainline We will need 4 pushbuttons to select the various tracks in the yard or main We designated the yard as tracks 2 3...

Page 4: ...Accessory 1 turnout 1 to the Normal straight position Button 2 will need to send Accessory 1 to Reverse diverging position Accessory 2 to Reverse diverging Button 3 will need to send Accessory 1 to Re...

Page 5: ...when button 1 is pushed Press 1 to send an accessory command INP 01 STEP 1 ACCY NUMBER Type the accessory number 1 followed by ENTER Allowable NMRA accessory addresses are 1 2044 Accessory number 2044...

Page 6: ...y input by grounding that input number Pressing any button on the ProCab will return the Mini Panel to setup mode Finishing programing At this point we have programmed reviewed and tested the command...

Page 7: ...UT NUMBER 30 We want to continue with the remainder of the command steps from input 1 at input 30 We will start programming the inputs with input number 1 Type 3 0 followed by ENTER to program input n...

Page 8: ...nt a 1 second delay The 4 second interval will be too long so press 2 to select the second interval delay command SELECT CMD GROUP NUM 1 4 SEC 00 Press 4 followed by ENTER to introduce a 1 second dela...

Page 9: ...U MENU NAVIGATION CHART 1 ACCY 2 MACRO 3 LOCO 4 SIGNAL 5 OTHER ACCY NORM or REV MACRO 1 SELECT 2 SPEED 3 FUNCTIONS LOCO 1 28 MODE 2 128 MODE SIGNAL ASPECT 1 F0 F4 2 F5 F8 1 DELAYS 1 4 SECs 2 1 4 SECs...

Page 10: ...inputs The sending of commands when certain inputs are grounded can be disabled Continuous Memory Command strings are normally limited to 4 commands per input unless you LINK to another command This...

Page 11: ...b Switch It the NCE logo with Power of DCC slogan are trademarks of NCE Corporation The distinctive shape of the ProCab when used with a thumb wheel speed control and LCD display is a trademark of NCE...

Reviews: