Appendix
– Technical Data
Position Indicator (A-CS-SYSECPI)
65
9
9.5 Position Indicator (A-CS-SYSECPI)
Figure 9-4: Dimensions of Position Indicator and Junction Box
9.5.1 Technical Data
Switching distance
max. 20 mm (0.79 in.)
positioned to steel St37, sized 50 mm in square (2.16 in. in square)
Temperature range
position indicator: -25 to 230°C (-13 to 446°F)
junction box:
-25 to 70°C (-13 to 158°F)
Length of cable
5 m (15 ft)
Protection rate:
IP67
Output
No. 2: active 24 V / 300 mA max.
short circuit protected
Junction Box
Pin 2 (brown cable): + 24 VDC (7 to 40 VDC), ripple max. 15 %
Pin 3 (black cable): output active
Pin 1 (blue cable):
0 V
Junction box
T
rig
g
e
r b
a
r
Position indicator
PG9 cable gland for
field cable
Mounting hole
d=5.2 mm (0.205)
Mounting hole
d=5.2 mm (0.205)
Electronic component
with cable to the sensor head