Accessories
Shadow Monitoring (A-CS-SM-KIT-485)
41
6
6.4 Shadow Monitoring (A-CS-SM-KIT-485)
The linescanners can be hindered from monitoring the complete kiln by physical obstructions and by shadows from
the tires. With the shadow monitoring kit additional pyrometers can be installed and configured to monitor these
“shadowed” portions. The temperature values from these pyrometers are integrated in the scanned data from the
linescanners and the results are displayed as one homogenous thermogram.
For an overview of a system configured with
Shadow Monitoring, see section 8.2
6.4.1 Technical Data
Temperature range
-40 to 600°C (-40 to 1112°F)
Spectral response
8 to 14 µm
Accuracy
± (1% of reading or 1°C) whichever is greater
Optical resolution
10 : 1 (90% energy)
Head ambient temperature
0 to 180°C (32 to 356°F)
Head cable length
8 m (26 ft.)
Protection rate (head)
IP65 (NEMA-4)
Digital interface
RS485
For other technical data see MI3 operators manual.
6.4.2 Delivery
The scope of delivery for the Shadow Monitoring accessory:
•
MI310LTH sensor and MI3 Communication Box (metal) with RS485 communications
•
Air purge jacket, stainless steel
•
Adjustable mounting bracket
•
Connection box
6.4.3 Mounting
The recommended sensor mounting is shown in the figure below. The angular alignment of the sensor head
reduces the risk of possible contaminations on the optics.
Figure 6-7: Recommended Alignment of Shadow Sensor
Shadow Sensor
Kiln