4 Installation and Connection
<Equipment side mounting part recommended machining dimensions>
4. After tightening the screws, make sure that there is no gap
between the unit and the lock adapter, or the lock adapter
and the partner device.
※ When attaching the lock adapter, about 10° of backlash is
generated.
To compensate for the backlash, refer to the Dedicated
Software (EPU-COM) Instruction Manual.
・
Do not forcibly assemble the unit and the lock adapter.
This may result in a
fault.
・
Make sure that no foreign objects, such as metal fragments, enter the lock
adapter.
This may result in a fault.
・
Do not hold the cables or output shaft during transportation.
This may result
in a fault.
・
Do not subject the output shaft to strong impacts.
This may result in a fault.
・
When installing the unit vertically, install the unit with the output shaft facing
down, as failing to do so may result in grease flowing into the unit.
This may
result in a fault.
32H7
48
45°
When fixing from equipment side: 4×Φ4.5
When fixing from the unit side: 4×M3
Caution