                                                Pellet silo assembly.

The pellet silo…..

As the pellets that you put into the silo contain dust, you should empty the silo 
completely from time to time. The more dust that is in the silo, the less pellets 

the feed screw will release and the boiler will become unadjusted, leading to 
inefficiency and possible breakdown.

How often the silo needs emptying completely, depends on the design of the silo 
and the quality of the pellet fuel used.

Page 6

Summary of Contents for Scotte 16kw

Page 1: ...Scotte Opop Installation and operating Manual 16 24 30kw NORDIC BIO ENERGY LTD Pellets Systems...

Page 2: ...screw and pellet silo assembly page 5 6 Section 4 Installation Boiler connection page 7 Flue pipe connection page 7 Section 5 Operating the burner First time start up page 8 Adjusting the burner page...

Page 3: ...ing has to be carried out in accordance with Building Regulations Republic of Ireland Part F Ventilation Part J Heat Producing Appliances Article 41 in N Ireland Part J in England and Wales and F in S...

Page 4: ...tent litres 26 35 56 105 Weight kg 160 200 245 335 Connections 1 1 1 2 Page 3 Burner boiler type Scotte OPOP Output 16 24 30 kW Classification EN 303 5 3 Test pressure 4 0 Bar Max operational pressure...

Page 5: ...Dimensions of burner and wiring diagram Page 4...

Page 6: ...hose to the top of the inlet tube on the burner unit and the other end of the thermoplastic hose to the outlet of the feed screw 2 mount the feed screw over the burner so the pellets can fall into th...

Page 7: ...completely from time to time The more dust that is in the silo the less pellets the feed screw will release and the boiler will become unadjusted leading to inefficiency and possible breakdown How oft...

Page 8: ...fault Flue pipe and chimney connections Use the correct flue size for boiler model table 1 page 3 Ensure adequate height of chimney to gain satisfactory draw and to prevent back draft A suitable cowl...

Page 9: ...first time start up refer to quick start guide on page 15 The outputs for high and low loads are run by the control system in a 100 step modulation and the changes between the different steps are mad...

Page 10: ...d there will also be the risk of a breakdown 3 Feed screw in high load factory settings 33 6 press the UP or DOWN buttons to adjust the quantity of pellets that corresponds to the blower speed It is i...

Page 11: ...rol Standard 0 OFF C2 Calibrating sensor 0 C3 Time with low O2 before stopping pellets Standard 30 min D1 Times of starts each day Standard 0 x D2 Max running time on each start Standard 60 min D3 Fir...

Page 12: ...ning The boiler The boiler should be emptied from ash and all of the surfaces should be brushed in order to remove soot particles Pay particular attention to ash in the exhaust deflector and the flue...

Page 13: ...IS NOT MOUNTED 1 the connector is not mounted correctly 2 dirt in the connector 3 sensor defective Check the connector on the burner Clean pellet debris dust from the connector Change the sensor photo...

Page 14: ...emperature safeguard with sensors 5 Pump 6 Safeguards set 2 5 bars 7 Pressure expansion 8 Return valve with remote sensors Tap 9 Thermometer 10 Return valve 11 Taps 12 Hot water containers 13 Feed 14...

Page 15: ...ce Engineers are trained to ensure that your wood pellet burning equipment works safely and efficiently A list of Service Engineers in your area is available from Green Energy Solutions They will chec...

Page 16: ...Page 14...

Page 17: ...power the DOWN key stops feed screw 2 Run pellets in a bucket for 15 min Amount 360 sec Pellets 6 min Read the result on the back side Put in the numbers in menu 2 3 4 The feed screw is stopped on do...

Page 18: ......

Page 19: ...Quick Start 16kw NBE Pellets Systems Estimating Table...

Page 20: ...Quick Start NBE Pellets Systems Estimating Table...

Page 21: ......

Page 22: ...Quick Start NBE Pellets Systems Estimating Table...

Reviews: