Step 5

  

Attach the 

AR1POA

 roof panels on the outer edges of the shelter nearest to 

the end panels and the 

AR1PIA

 pannels need to be equaly spaced along 

the centre.

Cap off the top using 

AR1CUTO

 and 

AR1CUTI

 as shown below.

Use the 

AR1TS

 strips to cover the gaps between the panels.

Once the shelter is in the final position and square, it can be scured to 

the ground using the 

FT3

 and 

FT1

 brackets and concrete bolts.

Summary of Contents for SR8061-F

Page 1: ...Assembly Instructions Shelter type SR8061 F SR8061 F 02 29102021 USA...

Page 2: ...14 15 14 12 17 11 13 13 6 1 3 4 18 10 7 1 8 5 16 9 2 19 19 2 3 2 Overall Shelter sizes...

Page 3: ...Outer ARFSO 41 5 4 10 ARFSI Apex Roof F Section Inner ARFSI 40 75 4 11 AR1CLTO 1m Apex Roof Centre Lower Trim Outer AR1CLTO 41 4 2 12 AR1CUTO 1m Apex Roof centre upper trim outer AR1CUTO 41 5 2 13 AR1...

Page 4: ...4 FIXINGS...

Page 5: ...K CORRECT ALIGNMENT Please note 1 5 Tec Screws are for roof panels only S1C CB1 CB1 JF1 JF1 ENSURE CORRECT ALIGNMENT ON CORNERS JF1 JF1 CB1 Step 1 Assemble S1C frames to make up the main structure usi...

Page 6: ...JF1 ST3 CB1 CB1 CB1 Step 2 Use JF1 and CB1 brackets to attach the S1C frame and ST3 Tie bar 6...

Page 7: ...75 40 75 40 75 ENSURE CORRECT ALIGNMENT OF RAFTERS AND S1C FRAMES Step 3 Attach AR1R rafters using DR brackets Secure the AR1IS END PANELS to S1C frames using tec screws The end rafters need to be pl...

Page 8: ...ARFSO ARFSO ARFSI ARSCLTO ARFSI DETAIL A SCALE 1 2 8 Attach the AR1CLTO and AR1CLTI to the top of the rafters The AR1CLTO are to be lined up near the end panels and the AR1CLTI have to be spaced equal...

Page 9: ...9 Step 5 Attach the AR1POA roof panels on the outer edges of the shelter nearest to the end panels and the AR1PIA pannels need to be equaly spaced along the centre Cap off the top using AR1CUTO and A...

Page 10: ...164 88 42 34 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides...

Page 11: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Reviews: