background image

14

15

14

12

17

11

13

13

6

1

3

4

18

10

7

1

8

5

16

9

2

19

19

2

3

2

Overall Shelter sizes

ITEM 

NO.

PART 

NO.

DESCRIPTION

DIMENSION

IMAGE

QTY.

1

S1C

Frame

2000 x 1035

8

2

JF1

Joint Flat - JF1

110 x 40

9

3

CB1

Corner Bracket - CB1

110 x 110 x 

40

9

4

ST3

Roof Tie

2060

1

5

FT3

FT3 Bracket

40 x 80 x 106

7

6

FT1

FT1 BRACKET

40X40X100

2

7

DR

Rafter Bracket

110 x 40 x 52

16

8

AR1R

1m Pitch Rafter

Default

5

9

AR1CL

TO

1m Apex Roof Centre 

Lower Trim Outer

1052

2

10

ARFSO

F - section outer

1055

4

11

AR1TS

Pitch Roof Trim Strips

630 x 60

6

12

AR1C

UTO

1m Apex Roof Centre 

Upper Trim Outer

1055

2

13

AR1IS

1m Pitch Infill Panel 

Shallow

1150x344

2

14

AR1P

OA

AR1 Roof Panel Outer

1055x620

4

15

AR1PI

A

Roof Panel Inner

1035x620

4

16

AR1CL

TI

1m Apex Roof Centre 

Lower Trim Inner

1035

2

17

AR1C

UTI

1m Apex Roof Centre 

Upper Trim Inner

1035

2

18

ARFSI

F - section inner

1035

4

19

EC40

40x40 PLASTIC END 

CAP

STD. STOCK 

ITEM

2

Summary of Contents for SR8061-F

Page 1: ...Assembly Instructions Shelter type SR8061 F SR8061 F 02 29102021 USA...

Page 2: ...14 15 14 12 17 11 13 13 6 1 3 4 18 10 7 1 8 5 16 9 2 19 19 2 3 2 Overall Shelter sizes...

Page 3: ...Outer ARFSO 41 5 4 10 ARFSI Apex Roof F Section Inner ARFSI 40 75 4 11 AR1CLTO 1m Apex Roof Centre Lower Trim Outer AR1CLTO 41 4 2 12 AR1CUTO 1m Apex Roof centre upper trim outer AR1CUTO 41 5 2 13 AR1...

Page 4: ...4 FIXINGS...

Page 5: ...K CORRECT ALIGNMENT Please note 1 5 Tec Screws are for roof panels only S1C CB1 CB1 JF1 JF1 ENSURE CORRECT ALIGNMENT ON CORNERS JF1 JF1 CB1 Step 1 Assemble S1C frames to make up the main structure usi...

Page 6: ...JF1 ST3 CB1 CB1 CB1 Step 2 Use JF1 and CB1 brackets to attach the S1C frame and ST3 Tie bar 6...

Page 7: ...75 40 75 40 75 ENSURE CORRECT ALIGNMENT OF RAFTERS AND S1C FRAMES Step 3 Attach AR1R rafters using DR brackets Secure the AR1IS END PANELS to S1C frames using tec screws The end rafters need to be pl...

Page 8: ...ARFSO ARFSO ARFSI ARSCLTO ARFSI DETAIL A SCALE 1 2 8 Attach the AR1CLTO and AR1CLTI to the top of the rafters The AR1CLTO are to be lined up near the end panels and the AR1CLTI have to be spaced equal...

Page 9: ...9 Step 5 Attach the AR1POA roof panels on the outer edges of the shelter nearest to the end panels and the AR1PIA pannels need to be equaly spaced along the centre Cap off the top using AR1CUTO and A...

Page 10: ...164 88 42 34 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides...

Page 11: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...