General information

Standard scope of delivery

 

 –  Transmitter including carrying system 
–  Receiver with integrated mounting holes 
–  Integrated connection cable or adapter cable for receiver 
 
The order confirmation and/or delivery note is binding for the actual scope of delivery.

Safety information

 

 Even if you have already operated radio control systems, always read these operating  
instructions before commissioning. Only these operating instructions include the latest  
information about your NBB radio control system.

 

 Please refer to the enclosed documents for explanations about the operating license. Always observe 
the relevant work safety and accident prevention regulations. Only trained and authorized persons may 
operate the NBB radio control system. The safety features installed in the NBB radio control system 
must be checked regularly.

 

 The NBB radio control system must be shut down immediately in case of failures. The transmitter 
must be switched off using the EMERGENCY STOP switch or STOP button. The connection cable 
at the receiver must be disconnected from the connection (terminal) of the controlled system. 
The radio control system may only be repaired by NBB or specialists authorized by NBB.

 

  Disregarding these recommendations puts you and others in danger!  
NBB refuses any warranty and liability in such cases. The radio control system is used to control machines 
and transmit data. In explosive atmospheres or for the control of machines for the transport of persons 
it may not be used, unless specifically authorized by the manufacturer for this application. Any different 
use is prohibited and releases NBB from any responsibility.

Nameplates

 

 The nameplates specify transmitter and receiver type, serial number, frequency range and approval  
for non-EU countries. Please always advise serial number for queries.

 

 Never expose the radio control system to strong jet high pressure cleaning equipment! 

Edition 05/18

Summary of Contents for Compact-V 9600 Baud

Page 1: ...onents GmbH Flexibly designed complete solutions Radio Control Systems Cable Control Systems Infrared Control Systems Operating instructions Radio Control System MS Compact V 9600 Baud Transmitter Tra...

Page 2: ...NBB Controls Components GmbH 2...

Page 3: ...Contents 3 General information 4 Transmitter Nano L SMJ 7 2V 6 Receiver Compact V 9600 Baud 12 Accessories 16 Technical documents 20...

Page 4: ...NBB radio control system must be shut down immediately in case of failures The transmitter must be switched off using the EMERGENCY STOP switch or STOP button The connection cable at the receiver must...

Page 5: ...at the expense of the buyer Worn parts relays rechargeable batteries and batteries are excluded from the warranty The functional warranty does not cover damage accidental damage negligence improper u...

Page 6: ...ter Nano L SMJ 7 2V Variations Nano L SMJ 7 2 V with 3 Joysticks Nano L SMJ 7 2 V with Display and 4 Joysticks Nano L SMJ 7 2 V with Display and 2 Joysticks Nano L SMJ 7 2 V with 2 Joysticks Nano L SM...

Page 7: ...rvice life Safety equipment Safety equipment in the NBB radio control system EMERGENCY STOP or STOP function Zero position interlock Addressing each transmitter using a unique Binary bit code combinat...

Page 8: ...position If necessary release the emergency stop pushbutton by turning clockwise To ensure faultless free operation please observe the following rules The system to be controlled provided the transmit...

Page 9: ...time bring the unit into a safe position switch off the transmitter and replace the batteries with charged batteries Energy saving function If no buttons are pressed within a specified time the transm...

Page 10: ...Surface Mounted Joystick see below Surface Mounted Joystick teach mode activation with pushbutton To activate teach mode the transmitter must be switched off 1 Press and hold the Frequency switching k...

Page 11: ...ttons to enter and store min and max values for valves could differ from the description above In this case a separate supplemental information sheet will be attached to the operating instructions Tec...

Page 12: ...12 NBB Controls Components GmbH Receiver Compact V 9600 Baud Variations Compact VC Compact VB Compact VD Compact VE Edition 12 15...

Page 13: ...tronics cannot be supplied Please make sure that the operating voltage of the receiver corresponds with the connection plans of the system to be controlled The valid operating voltage is noted in the...

Page 14: ...OP switch or STOP button at the transmitter until the switch engages Then observe if the unit to be controlled is switched off time to switch off according to the application Meaning of the LED displa...

Page 15: ...on 16 million options Safety EMERGENCY STOP with self test Restart lockout in the event of a faulty EMERGENCY STOP relay Contact load of EMERGENCY STOP relay Max 4A 250V AC Contact load of relay Max 6...

Page 16: ...16 NBB Controls Components GmbH Accessories Battery 7 2V and charger for 7 2V battery NiMH battery 7 2V Charger for charging NiMH rechargeable batteries 7 2 V Edition 11 15...

Page 17: ...r subject it to strong impact Protect the battery from rain moisture and extreme temperatures Keep the contacts clean and make sure the battery does not come into contact with metal objects e g alumin...

Page 18: ...tates Undervoltage Pre charging with reduced charging current Insufficient temperature Pre charging with reduced charging current warm up Excessive voltage No start of charging procedure Shutdown when...

Page 19: ...integrated charger Quick charging approx 1h R16 R CAN Compact M Compact V Normal charging approx 3h PNN BUS 3 Technical data Power supply 9V 32V DC e g by 12V 24V on board electrical system Note the...

Page 20: ...20 NBB Controls Components GmbH...

Page 21: ...21 Technical documents...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ...GN 12 V DC X1 3 Power Supply 0 V AC 9 F2 4A T IN_X6 2 Common 2 K11 Emergency stop OUT_X6 1 EMERGENCY STOP 3 K1 K1A B OUT _X6 3 Hoist UP DOWN 4 2 2 4 4 POT1 IN _X7 1 Common 5 K2 K1A B OUT_X7 2 Hoist U...

Page 27: ...mmon 29 K4 1 OUT_X10 K4 1 SW13 OUT_X11 Compressor OFF 30 IN_POT 5 Common 31 K5 1 OUT_X12 K5 1 SW09 OUT_X13 Spare ON on off 32 IN_POT 13 Common 33 K13 1 OUT_X17 K13 1 SW11 OUT_X18 Spare ON on off 34 IN...

Page 28: ...v1_4_v2_12 txt 7 segment display 1 FREQUENCY BAND 1 3 300 1605 FACEPLATE 2 korean frequency Charger 2s FM yes Auto Off no Active Passive LBT Mode 1 S_9600120085_v1_0 scd switch adapter board black bla...

Page 29: ...V013 E SW19A6 V1 3 BOARD 2 1 2 100 1270_V015 S AD06A0 V1 5 BOARD 1 1 2 100 1382_V013 E SW10A1 V1 3 silver printed FACEPLATE 1 3 820 1195 black LOWER PART 1 3 300 1503 PROGRAM 2 UPPER PART 1 2 250 1500...

Page 30: ......

Page 31: ......

Page 32: ...ls Components GmbH Otto Hahn Stra e 3 5 75248 lbronn D rrn GERMANY Fon 49 7237 999 0 Fax 49 7237 999 199 sales nbb de www nbbcontrols de Edition 05 18 We reserve the right to alter specifications with...

Reviews: