User Manual
8
9
Filter Cleaning
Error Display
Natural Drainage / Drainage Pump Installation
1. Remove right hand side panel(
①
) from the
dehumidifier after loosening two bolts.
2. Connect drain hose(
③
) to drain hole(
②
) of the
dehumidifier and take it out through the hole in
the bottom of the back of the product.
3. Fix the right side plate(
①
) to the product again.
* Natural drain hose size : Outer diameter Ø25,
Inner diameter Ø16
1. Remove air inlet cover by pulling forward.
2. Press down the handle attached on the filter and pull
forward to remove.
3. Clean filter.
4. Please re-fitted after cleaning.
* Caution : Please be aware that excessive force may
damage to the cover of air inlet.
Natural Drainage
To Clean The Filter
Drainage Pump Installation
①
③
①
③
②
②
⑥
④
⑤
①
③
①
③
②
②
⑥
④
⑤
1. Remove right hand side panel(
①
) from the
dehumidifier after loosening two bolts.
2. Fix the pump(
③
) to the bottom of the
dehumidifier.
3 Connect natural drain hose to drain hole(
②
) of
the dehumidifier and insert into the inlet(
⑥
) of
the drain pump.
4. Connect auto drain hose to discharge port(
④
) of
drain pump and take it out through the hole at
the bottom of the back side of the dehumidifier.
5. Fix the right side plate(
①
) to the product again.
* Auto drain hose size : Outer diameter Ø12,
Inner diameter Ø8
* In case of drain hose mounted type, use with drain hose inserted into ONE-TOUCH CLIP(
⑤
) on the back side.
* Drain hose and drainage pumps are going to buy a service center.
Indoor temperature
checking
When indoor temperature is less than 18
℃
,
"rt Lo"
will be displayed.
(This is not a failure.)
Indoor temperature
checking
When indoor temperature is more than 50
℃
,
"rt Hi"
will be displayed.
Check sensor
If the temperature sensor line is disconnected or short-circuit,
"Err 1"
will be displayed.
Check sensor
If the EVA discharge sensor line is disconnected or short-circuit,
"Err 2"
will be displayed.
Check sensor
If the EVA sensor line is disconnected or short-circuit,
"E3"
will be displayed.
Hi-pressure
check
If compressor pressure gets high, high-pressure detection switch
operates, compressor stops and
"Err 4"
will be displayed.
Low-pressure
check
If compressor pressure gets low, low-pressure detection switch operates,
compressor stops and
"Err 5"
will be displayed. In this case, check if there
is leakage by checking pressure of refrigerant pipe.
To prevent freezing of the evaporator, the compressor stops and
"Err 6"
will be displayed if the sensor continues to display below -7
℃
.