20 | Confidential
Digital Output
ConEx Digital I/O -2 (green wire) can be configured as an output thru OnlineAVL2. This output will pull
low with a maximum current of 250mA when activated. Standard automotive relay is required for most
applications. Access to this feature and configuration is available thru OlineAVL2.
ConEx Sensor Monitoring
(cont.)
+12V
Green – Digital I/O-2
x
*Disconnect a circuit
+12V
Green – Digital I/O-2
*Activate a light or buzzer
85
86
30
87A
87
85
86
30
87A
87