NAVMAN D100 User Manual

Installation

Location

The NAVMAN D100 is designed for above or
below deck installation. Select a position that is:

• At least 300mm from a compass

• At least 500mm from any radio

• Easy to read by the helmsman and crew

• Protected from physical damage

• Accessible to electrical cable connections

Mounting

The mounting surface must be flat. Use the
template to set the centre of the fixing hole.

• Drill a 32mm (1.25”) diameter mounting hole

through the bulkhead.

• Remove the fixing nut. Peel the protective

paper off the foam gasket and attach the
gasket to the rear of the instrument.

• Insert the instrument through the bulkhead.

Hand tighten the nut and then finally tighten
with a spanner. Do not over tighten so that
the water sealing ability of the gasket is
damaged.

112mm

(4.4”)

4.5mm

(1.75”)

30mm

(1.2”)

112mm

(4.4”)

24mm

(1”)

56mm

(2.2”)

35mm

(1.4”)

Summary of Contents for D100

Page 1: ...DEPTH NAVMAN NAVMAN...

Page 2: ...g 5 Wiring Connection 6 Multiple Instruments 6 Operation 7 Select Units 7 Backlighting On Off 7 Depth Alarm On Off 7 Setting Alarms 8 Set Shallow Alarm 8 Set Deep Alarm 8 Secondary Functions 9 Set Dis...

Page 3: ...res 0 5 to 67 fathoms or 3 to 400ft Alarms Shallow and deep water Audio and LCD flag Display unit selection Feet metres or fathoms keypad selectable Display Damping Three levels keypad selectable Keel...

Page 4: ...The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole through the bulkhead Remove the fixing nut Peel the protective paper o...

Page 5: ...provide protection for up to five 100 series instruments Multiple Instruments The NAVMAN D100 may be used as an individual instrument or connected with a number of other 100 series instruments to the...

Page 6: ...hting On Off Simultaneously press the FEET MTRS FATH and keys to turn the backlight on Repeat this procedure to turn the lighting off FEET MTRS FATH SHALLOW DEEP FEET MTRS FATH SHALLOW DEEP Depth Alar...

Page 7: ...er alarm sounds when the depth exceeds the selected value When the alarm is activated the beeper will sound continuously and the bell alarm symbol will flash Set Shallow Alarm MTRS SHALLOW Use the and...

Page 8: ...n when power is switched off Repeat this procedure to exit simulation mode Note Settings that are made while in simulation mode will remain in effect after returning to normal mode Secondary Functions...

Page 9: ...ngs while moored Check transducer for growth or multiple coats of paint Erratic readings while underway Cavitation air under the face of the transducer Review installation and reinstall if necessary W...

Page 10: ...water performance and reduced deep water performance There are three values of transducer settings 1 to 3 The lower numbers improve the shallow water performance and may produce reliable readings to b...