Specifications

• Power supply

10.7 to 16.6 VDC  15 mA nominal, 35mA
with backlight on.

• Operating temperature

0°C to 45°C.

• Size of display

112 x 112 x 20mm (4.4 x 4.4 x 1”). Overall
depth 35mm (1.4”) behind panel.

• Display type

Twisted Nematic (TN) grey background,
0°C to +70°C.

• Illumination

Red LED switchable from front panel.

• RF Interference

Less than 6 dB maximum quieting on any
marine radio channel with 3 dB gain antenna
within 1 metre of instrument display head
(European EC specifications).

• Depth

1 to 130 metres, 0.5 to 67 fathoms or 3 to
400ft.

• Alarms

Shallow and deep water. Audio and LCD
flag.

• Display unit selection

Feet, metres or fathoms, keypad
selectable.

• Display Damping

Three levels keypad selectable.

• Keel Offset

Keel or waterline, ±9.9 ft, ±1.6 fathoms or
±3.0 metres, user resettable.

• Trend Indication

Arrows indicate increasing or decreasing
depth trend.

• NMEA Outputs

DPT, DBT.

• Proprietary Outputs

Alarm and Trend arrows.

• Transducer

200 kHz, 600 ohm, 1500pF parallel
capacitance.

DEPTH

FEET MTRS FATH SHALLOW DEEP

Change Value Up

Depth is decreasing

Indicates alarm is on

Depth is decreasing

Deep Alarm

Set/Indicator

Shallow Alarm

Set/Indicator

Display is backlit for
Night Operation

Indicate depth units

Alarm On/Off

Change Value Down

Summary of Contents for D100

Page 1: ...DEPTH NAVMAN NAVMAN...

Page 2: ...g 5 Wiring Connection 6 Multiple Instruments 6 Operation 7 Select Units 7 Backlighting On Off 7 Depth Alarm On Off 7 Setting Alarms 8 Set Shallow Alarm 8 Set Deep Alarm 8 Secondary Functions 9 Set Dis...

Page 3: ...res 0 5 to 67 fathoms or 3 to 400ft Alarms Shallow and deep water Audio and LCD flag Display unit selection Feet metres or fathoms keypad selectable Display Damping Three levels keypad selectable Keel...

Page 4: ...The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole through the bulkhead Remove the fixing nut Peel the protective paper o...

Page 5: ...provide protection for up to five 100 series instruments Multiple Instruments The NAVMAN D100 may be used as an individual instrument or connected with a number of other 100 series instruments to the...

Page 6: ...hting On Off Simultaneously press the FEET MTRS FATH and keys to turn the backlight on Repeat this procedure to turn the lighting off FEET MTRS FATH SHALLOW DEEP FEET MTRS FATH SHALLOW DEEP Depth Alar...

Page 7: ...er alarm sounds when the depth exceeds the selected value When the alarm is activated the beeper will sound continuously and the bell alarm symbol will flash Set Shallow Alarm MTRS SHALLOW Use the and...

Page 8: ...n when power is switched off Repeat this procedure to exit simulation mode Note Settings that are made while in simulation mode will remain in effect after returning to normal mode Secondary Functions...

Page 9: ...ngs while moored Check transducer for growth or multiple coats of paint Erratic readings while underway Cavitation air under the face of the transducer Review installation and reinstall if necessary W...

Page 10: ...water performance and reduced deep water performance There are three values of transducer settings 1 to 3 The lower numbers improve the shallow water performance and may produce reliable readings to b...

Reviews: