background image

24

http://machinevision.navitar.com  

 

•                     email: [email protected]

Zoom 6000 High Mag Zoom Lenses

Polarizers 

Polarization is a contrast enhance-
ment technique that can reduce 
back reflections and bring out 
salient features not readily visible 
with normal viewing.

If you choose to add a polariza-
tion option to your lens system, it 
requires an illumination polarizer 
(2-62827), an analyzer above the 
zoom, a quarter wave plate (op-
tional), and a shorter version of an 
Adapter (RA) because the analyzer 
shortens the optical path by
50.8 mm.

Analyzer 

When used in conjunction with a 
polarized light source, an analyzer 
(1-60816) allows for cross polar-
ization of the light in the imaging 
system. This reduces reflections 
that can deteriorate the image 
quality. The analyzer must be used 
in conjunction with the right angle 
adapters.

Aperture Control 

Lens systems can be designed with 
an internal iris that can be manipu-
lated without cutting into the field 
of view. The iris permits the reduc-
tion of image intensity at the image 
plane, which reduces “blooming” 
and other damaging artifacts. The 
iris can also be closed down to 
essentially “stop down” the lens 
to reduce the Numerical Aperture 
of the lens. This narrowing of the 
light gathering cone produces a 
significant increase in the depth of 
field (the thickness of the envelope 
at the object, where various object 
heights are still in reasonable 
focus).

To have an aperture control feature 
designed into your system place an 
“A” after the standard part
number.

Quarter Wave Plate

A quarter wave plate (1-60981) has 
the unique feature of taking the 
polarized light and circularly polar-
izing the beam (sort of a spiraling 
effect). When this beam reflects 
off a specular object, the spiraling 
reverses, and upon re-striking the 
quarter wave plate, the beam is ex-
tinguished. This technique is useful 
in eliminating reflections from 
wafers and circuit boards. At other 
times, the quarter wave plate is 
used to add contrasting coloration 
to appropriate objects. For use with 
Zoom 6000 Coaxial lens. 

Infinity Corrected 
Objectives

Infinity Corrected Objectives can 
be attached to the Zoom 6000 
UltraZoom to increase the sys-
tem magnification and decrease 
working distance. Navitar offers 
Mitutoyo long working distance 
objective lenses in magnifications 
of 5X, 10X, 20X, 50X (1-60226, 
1-60227, 1-60228 and 1-60229) 
and Motic long working distance 
objective lenses in magnifications 
of 5X, 10X and 20X (1-62828, 
1-62829, 1-62830).

Accessories 

continued

Summary of Contents for Zoom 6000

Page 1: ...h contrast images and vivid colors help your equipment perform better 0 01 125 68 mm field coverage allows you to view a wide range of parts Working distance can be varied from 34 to 390 mm Add infini...

Page 2: ...lens system incorporates Navitar s world renowned optics This building block design can be config ured to fit nearly any application 6 5 1 Zoom Ratio Long Working Distance and Large Field of View The...

Page 3: ...ariation in magnification across the field of view Field Field of view for respective camera format normally measured diagonally Magnification A measure of the apparent differences in size between the...

Page 4: ...1 6010 1X NIRA T 1 60182 C Mount Coupler 1 6010 2X F Mount 1 62922 5X 1 6105 2X 1 6030 1X 1 6015 1X T 1 6218 67X 1 6020 0 5X 1 60439 2X 1 62136 1 33X T 1 61387 1X 1 61400 0 67X T 1 61001 0 5X T 1 6262...

Page 5: ...3mm Microscope Eye Piece sold separately Eye Piece Holder 1 6050 NIRA Mount w Prism 1 60165 Mount 1 6080 Analyzer 1 60816 Aux Viewing Port 1 60370 B L Leica Adapter Plate 1 6055 Stand 82mm 1 6206 Moun...

Page 6: ...46 4 74 22 69 3 56 15 23 2 37 11 45 1 78 7 62 1 19 4 35 68 3 05 0 47 9 80 3 14 1 73 0 18 Field 2 3 30 50 6 52 31 21 4 89 20 95 3 26 15 75 2 45 10 48 1 63 5 98 93 4 19 0 65 9 80 3 14 1 73 0 18 None 0...

Page 7: ...n navitar com Zoom 6000 System Dimensions Lenses Adapters Attachments All measurements are in mm unless otherwise specified 6 5X w 12 mm F F 1 60135 6 5X w 3 mm F F Int Coax 1 60123 6 5X w 3 mm F F 1...

Page 8: ...18 0 75x 6 5X Zoom 5 0x 113 2 63 16 88 0 017 0 053 9 80 3 14 25 74 53 09 1 73 0 18 None 6 5X Zoom 0 5x 92 0 35 2 25 0 023 0 071 7 25 2 35 2 54 5 28 0 95 0 10 None 6 5X Zoom 0 67x 92 0 47 3 00 0 023 0...

Page 9: ...0 002 2 250 0 004 2 500 0 007 2 750 0 010 3 000 0 009 3 250 0 010 3 499 0 012 3 749 0 014 3 999 0 016 4 249 0 019 4 499 0 021 Zoom 6000 Distortion Percentage This data is plus minus calibrated distort...

Page 10: ...51 2 28 0 36 Field 2 3 2 11 06 4 89 2 11 54 3 60 11 40 2 44 11 0 1 83 7 86 1 22 4 49 0 7 3 14 0 49 1 5X 0 034 0 104 1 60112 51 nominal 51 53 1 W D range Mag 0 53X 3 38X 0 71X 4 50X 1 05X 6 75X 1 4X 9...

Page 11: ...14 NA 1 60226 34 Mag 1 74X 11 43X 2 3X 15 0X 3 48X 22 86X 6 1X 39 4X Field 1 4 2 30 0 35 1 74 0 26 1 15 0 17 0 65 0 1 Field 1 3 3 45 0 52 2 61 0 40 1 72 0 26 0 98 0 15 Field 1 2 1 4 05 0 70 3 48 0 54...

Page 12: ...the visible is known as Near Infrared NIR NIR is the electromagnetic band of wavelengths between 0 7 1 5 microns 700 1550nm When light strikes a glass surface a portion is bounced back thereby reducin...

Page 13: ...meter scale custom graphic over the video image on the monitor The information on the reticle must be contained to the size of the sensor For example if a 1 2 camera sensor is used the reticle must ha...

Page 14: ...6000 series Part 1 62866 is a right angle attachment designed with a mirror that can be used with all lens attachments except 2X 1 60113 Adapter Plates Zoom 6000 Accessories Adapter Plates Navitar of...

Page 15: ...r Low High 0 25X 0 018 N A 1 6044 356 Mag 0 35X 2 25X FOV 85 13 3 0 5X 0 035 N A 1 60110 175 Mag 0 7X 4 5X FOV 43 6 7 0 75X 0 054 N A 1 60111 113 Mag 1 05X 6 75X FOV 26 4 4 NONE 0 071 N A 92 Mag 1 4X...

Page 16: ...s split into two The two beams separated by a Accessories continued minuscule amount are polarized at 90 degrees to each other and one beam is shifted in relation to the other a phase shift If the sub...

Page 17: ...8mm Parallel Input 2 60263 10mm Input 2 61503 12mm Input 2 61955 M25 x 75T Objective Adapter 2 51370 Infinity Corrected Incident Light Objectives Not Available From Navitar Contact Your Local Sales r...

Page 18: ...the lens to reduce the Numerical Aperture of the lens This narrowing of the light gathering cone produces a significant increase in the depth of field the thickness of the envelope at the object where...

Page 19: ...es digicams com Attaches digital camera or camcorder to any C mount or standard SLR lens Permits digital recording of subject matter Includes a male M37 x 0 75 thread Fits any standard 30 mm microscop...

Page 20: ...e Field of View Calculator To use this calculator simply follow these easy steps 1 Insert the applicable sensor dimension and the desired working distance in either or both zoom style columns 2 Enter...

Reviews: