Display Functions

Auto Focus

To activate the auto focus, simply press the focus button for a short moment.
During the auto focus mode a LED will come up. To switch it off just press the
button again.

This function can also be done with a hand remote control.  If the auto focus
function is on, you can also use the manual correction. This overdrive function is
indicated with a blink on the focus LED.

Remote Control Connector

Timer

The SUPERNOVA 10K has a timer included to forward the slides. It is program-
mable between 2 and 99 seconds.

Programming the Interval Between the Slides

Press the timer button for at least 2 seconds and hold it for the desired interval
(the red LED flashes for  every second, for example, 8 flashes equals 8 sec-
onds). If you have reached your desired time, stop pressing the button. Now, the
timer is programmed.

Activating the Timer

Simply press the timer button for a short moment and the cycle will start non-
stop. The set time interval will remain in the projector’s memory even if the
projector is turned off.

Autoshow

The SUPERNOVA 10K includes an autoshow feature which is a useful tool when
using the timer to advance slides.

When using autoshow, the timer starts at slide 1 and advances the tray forward.
Autoshow recognizes if a slide is in the gate.  If there is a break of 2 empty slide
slots, autoshow will initiate a rapid homing and the cycle will start again with the
next available slide.

Remote Start

With a simple permanent closure contact connecting pin 9 and 5, the lamp will
ignite and the SUPERNOVA 10K will start operating.

After disconnecting pin 9 and 5, the unit will switch off the lamp and a 3 minute
after-cooling period will follow.  After that time it will return to stand-by mode.

Summary of Contents for 10K

Page 1: ...Navitar 10K High Intensity Slide Projector NAVITAR Inc 200 Commerce Drive Rochester New York 14623 USA Phone 585 359 4000 Fax 585 359 4999 Internet navitar com E mail info navitar com...

Page 2: ...m Diagrams 5 Available Models 6 Operation 7 Maintenance and Care 8 Projection Lenses 9 Slide Tray Use 10 Display Functions 11 Installing a New Lamp 14 Slide Recommendations 17 RS 232 Specifications 18...

Page 3: ...ve ultra violet ray which can be extremely dangerous for eyes and skin LOOKING DIRECTLY INTO THE LIGHT BEAM CAN CAUSE SEVERE DAMAGE TO THE RETINA AVOID LOOKING DIRECTLY INTO THE LIGHT BEAM ALWAYS ALLO...

Page 4: ...output the SUPERNOVA 10K uses a strong HTI metal halide lamp with power supply and suitable cooling for the slides Do not look into the light while the projector is in operation The SUPERNOVA 10K is...

Page 5: ...nt View Rear View Tray Adjustment Nose for Tray Adjustable Leg Adjustable Leg Adjustable Leg Projector Body Lens Tray Adjustment Nose for Tray LEDs Buttons Fan RS 232 Input Remote Control Power Connec...

Page 6: ...jections or faded projections When using a fading control unit the SUPERNOVA 10K automatically recognizes the type of control unit used and the fading results are optimized electronically SUPERNOVA10K...

Page 7: ...jector will run for approximately 3 minutes in the cooling mode After the cooling period the projector will turn off automatically When turned off the projector automatically proceeds to the zero posi...

Page 8: ...the main part of the projector on the left side It is used to take in air for proper ventilation Depending on the dust and dirt found in your projection environment the air filter might get clogged Th...

Page 9: ...e distance from the projector to the screen and the width of the projected image This means when using a lens size 3 4 1 the projector has to be 3 4 feet away to get a 1 foot wide projected image Exam...

Page 10: ...ro position and the tray can easily be removed The tray can only be removed in the zero position There is a safety mechanism which prevents taking the tray off in any other position Should it occur th...

Page 11: ...button the tray will go backwards By pressing backward and forward simultaneously the projector will go rapidly to the zero position No lamp Mode By pressing this button the unit will go into the no...

Page 12: ...your desired time stop pressing the button Now the timer is programmed Activating the Timer Simply press the timer button for a short moment and the cycle will start non stop The set time interval wil...

Page 13: ...your local dealer Reset By pressing the reset button the slide mechanism undergoes an electronic reset This is necessary in case you have a slide jam The unit is designed to blockade in such cases to...

Page 14: ...mp is off and cold there is no danger So make sure when changing the lamp that it is cold and completely turned off Make sure to use no force on the lamp when changing Change the lamp as follows 1 UNP...

Page 15: ...this by loosening the screws 6 Now you can remove the HTI lamp Grab the ceramic socket and pull it out easily Do not touch the glass part of the lamp It might affect the quality of your projection Wa...

Page 16: ...ert an empty slide no picture in the slot The lighter side of the frame must face the lamp 2 Wait about one minute for the lamp to reach maximum brightness You will see a white projection on the scree...

Page 17: ...mounts for one tray Although slide damage is unlikely when following the projector instructions we recommend using duplicate slides instead of original slides Slide Production For the production of yo...

Page 18: ...j00 Slide forward j01 Slide backward j05 Shutter open j06 Shutter close j07 Focus 1 step forward j09 Focus 1 step backward j11 Reset projector j12 Slide position j22 Projector version j23 Software ve...

Page 19: ...her improper servic ing or modification by someone other than Navitar Further this warranty does not cover any routine maintenance work that is reasonably expected to be performed by the purchaser No...

Page 20: ...While in use the lamps emit an intensive ultra violet ray which can be extremely dangerous for eyes and skin LOOKING DIRECTLY INTO THE LIGHT BEAM CAN CAUSE SEVERE DAMAGE TO THE RETINA AVOID LOOKING DI...

Reviews: