SECTION 3 – INSTRUMENTS, INDICATORS, AND SWITCHES
Air Cleaner Restriction Indicator
Air restriction is resistance of airflow through the air cleaner.
Accurate air restriction is measured at maximum airflow.
Figure 24
Air cleaner restriction indicator
Air cleaner restriction is measured by an air restriction indicator.
The restriction indicator may be located anywhere within the air
induction system or instrument panel depending on your specific
application.
Air Restriction Indicator Calibration
•
The indicator is calibrated in inches of water.
•
The indicator should be tested periodically (using a master
vacuum gauge) to ensure a correct calibration.
Air Restriction Indicator Operation
•
The yellow position indicator progressively fills the window
as air filter restriction increases, locking at the highest
restriction at full load.
•
When the yellow position indicator reaches and locks in the
red zone, a new air filter element should be installed.
NOTE:
If the yellow indicator locks in the red zone, it is not
necessary to shut down the engine immediately, but a new air
filter element should be installed at the earliest convenience.
Air Restriction Indicator Reset
•
Once the filter has been changed reset the air restriction
indicator as follows:
•
Push the button on the indicator to reset.
Form No. 1172040R1
Page 46
Printed in the United States of America
Summary of Contents for MaxxForce DT 9
Page 2: ...Form No 1172040R1 Printed in the United States of America ...
Page 8: ...Form No 1172040R1 Printed in the United States of America ...
Page 10: ...FOREWORD Form No 1172040R1 Page 2 Printed in the United States of America ...
Page 14: ...SAFETY INFORMATION Form No 1172040R1 Page 6 Printed in the United States of America ...
Page 102: ...SECTION 6 LONG TERM STORAGE Form No 1172040R1 Page 94 Printed in the United States of America ...