Industrial Cellular VPN Router NR500 Series User Manual
Page 39 / 70
Serial->Connection Settings
•
Baud Rate
Select the serial port baud rate. Supported values are 300, 600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, or 115200.
•
Data Bits
Select the values from 7 or 8.
•
Stop Bits
Select the values from 1 or 2.
•
Parity
Select values from none, even, odd.
•
Transmission Method
Select the transmission method for serial port.
Optional for “Transparent”, “Modbus RTU Gateway”
and “Modbus ASCII Gateway”.
•
MTU
Maximum Transmission Unit, maximum packet size allowed to be transmitted. Should be left as
default value of 1024 in most cases.
•
Protocol
Select the mode for Serial IP communication. Supported modes are UDP, TCP Server, or TCP Client.
•
Remote IP Address
Enter the IP address of the remote server.
•
Remote Port
Enter the port number of the remote server.
Below window displays different settings when you select
TCP Server
on Protocol.
Serial->Connection Settings
•
Local IP Address
Enter the IP Address of the local endpoint.
•
Local Port
The port number assigned to the serial IP port on which communications will take place.