Navien PeakFlowE GXXX001725 Installation, Operation And Maintenance Manual Download Page 4

4

Filter Cartridge Replacement Procedure

1.   IMPORTANT:  All other equipment connected to the 

PeakFlowE  system must be turned off prior to shutting 

off water supply from filters.

2.   Turn OFF water to PeakFlowE  system by closing the

 

Inlet Ball Valve.

3.  Press the red button to release pressure.
4.  Remove housing - use filter wrench if necessary. 
5.   Remove filterfrom housing.  Clean inside of housing with 

warm water.  If desired, disinfect housing by adding a 

teaspoon of household bleach to housing, fill with water, let 

stand for 5 minutes, and then discard.

6.   Insert new cartridge into filter housing. Match cartridge 

model number to model number on bracket.

7.  Check O-ring for damage and replace if damaged or   
 

 distorted.   Make certain the O-ring is properly positioned and

 

reinstall filter housing (hand tighten only).  

8.   Slightly open the inlet ball valve; push the red pressure 

relief button to release trapped air until a small amount of 

water comes out - release the red button and fully open 

the ball valve.

9.   Open the flush valve downline from the filter housing (if 

equipped) and flush the new cartridge to drain or bucket  

for two (2) minutes or until water runs clear. If no flush valve 

is present, disconnect line from equipment to flush to drain.

10.   VERY IMPORTANT:  With water supply inlet valve OPEN and 

water flow confirmed, turn on connected equipment. Failure 

to supply water to equipment may cause serious damage.

11.  Record filter change on the service log.

Maintenance

Routine maintenance of your PeakFlowE

TM

 System involves periodic 

filter cartridge changes and/or replacement of sump O-rings.  

If the system sizing recommendations have been followed,  

the PeakFlowE

TM

 cartridge should last two years. 

Filter Change Frequency

The filters should be changed in response to the following conditions.

GXXX001726 

 24 months since installation or last filter change. 

*Frequency of cartridge replacement will depend on volume of 

system usage.

Replacement Filter Cartridges

PeakFlowE

TM

 systems can only be used with PeakFlowE  filter 

cartridges. Use of replacement cartridges other than those  

specified will void warranties, certifications and may compromise 

equipment protection, water quality and equipment life. 

Operation

With sufficient pressure, operation of the Navien PeakFlowE

TM

System is completely automatic. Dependable operation involves 

only periodic filter changes and service documentation.

8.

4.

3.

2.

6.

7.

TM

TM

TM

Reviews: