4.6.17. Secondary Heat Exchanger
Navien Part No.
Function
Failure Event
1. Main part for heat transfer from the burner.
2. There is additional path of water pipes on the heat exchanger surface
as well as inside the combustion chamber and it minimizes the heat loss.
1. Water and/or exhaust gas leakage through a crack.
2. Improper heat transfer can cause the water in heat exchanger to boil.
1. The unit will stop operating once detecting water leakage.
2. Exhaust gas leakage.
3. Make boiling sound.
E001, E016, E030, E037
1. Visual inspection: check if there is a crack on the surface of heat exchanger.
2. Sound inspection: check if there’s boiling noise.
N/A
Effects
Error Code
Diagnostic
N/A
Check Point
N/A
Color /
Number of wires
Summary of Contents for NP-180
Page 2: ......
Page 39: ...Navien America Inc 2010 NR NP series service Manual 37 Version 2 0 4 4 2 NP A Model...
Page 40: ...Navien America Inc 2010 NR NP series service Manual 38 Version 2 0 4 4 3 NR Model...
Page 41: ...Navien America Inc 2010 NR NP series service Manual 39 Version 2 0 4 4 4 NP Model...
Page 174: ...Navien America Inc 2010 NR NP series service Manual 172 Version 2 0 Memo...
Page 175: ...Memo Navien America Inc 2010 NR NP series service Manual 173 Version 2 0...
Page 176: ...Memo Navien America Inc 2010 NR NP series service Manual 174 Version 2 0...
Page 177: ...Memo Navien America Inc 2010 NR NP series service Manual 175 Version 2 0...
Page 178: ...Memo Navien America Inc 2010 NR NP series service Manual 176 Version 2 0...
Page 179: ......