![Navien NP-180 Service Manual Download Page 59](http://html1.mh-extra.com/html/navien/np-180/np-180_service-manual_3836914059.webp)
©N
avien
Am
eri
c
a
I
n
c
.
20
1
0
NR/NP
series
servi
c
e
Manua
l
57
Versi
o
n
2.0
4.6.15. Flow Sensor
Navien Part No.
Function
Failure Event
1. To sensing water flow and GPM (Gallons per minute) for steady
hot water temperature.
1. Unable to detect or measure any water flow rate.
2. Water leakage from the water flow sensor.
1. Ignition sequence does not start.
2. Stop operating once detecting water leakage.
E039
1. Visual inspection: Connection and/or breakage of wires.
2. Voltage check: Check range of voltage shown below.
1. Red- black : DC 5 V
2. White – black : DC 0.3 ~ 4.5 V
Effects
Error Code
Diagnostic
AASS9EXFS003
Check Point
F
Color /
Number of wires
Flow Rate Range
Maximum Pressure
0.5 ~8.0 GPM
150 psi
Summary of Contents for NP-180
Page 2: ......
Page 39: ...Navien America Inc 2010 NR NP series service Manual 37 Version 2 0 4 4 2 NP A Model...
Page 40: ...Navien America Inc 2010 NR NP series service Manual 38 Version 2 0 4 4 3 NR Model...
Page 41: ...Navien America Inc 2010 NR NP series service Manual 39 Version 2 0 4 4 4 NP Model...
Page 174: ...Navien America Inc 2010 NR NP series service Manual 172 Version 2 0 Memo...
Page 175: ...Memo Navien America Inc 2010 NR NP series service Manual 173 Version 2 0...
Page 176: ...Memo Navien America Inc 2010 NR NP series service Manual 174 Version 2 0...
Page 177: ...Memo Navien America Inc 2010 NR NP series service Manual 175 Version 2 0...
Page 178: ...Memo Navien America Inc 2010 NR NP series service Manual 176 Version 2 0...
Page 179: ......