![Navien NCB-150E Service Manual Download Page 45](http://html2.mh-extra.com/html/navien/ncb-150e/ncb-150e_service-manual_3623910045.webp)
Version 1.4
44 NCB-E Service Manual
Item
Description
Display
(J) Heat Capacity
Display of current heat capacity %
range: 50-100%
Default : 100%
% Heat capacity display in percentage
ex) 100%,
(K) Flame State
Display of flame detection current
AD value
Flame ON : Below 70
Flame OFF : Over 175
Displays the flame by flame detection AD value (0-255) , ex) 200
(L) Target RPM
Target fan motor RPM display
Displays RPM deleting the 1st digit,
ex) 3600rpm,
(M) Current RPM
Current fan motor RPM display
Display of RPM by omitting the last digit, ex) 3600 rpm,
(N) Target APS
Target APS voltage value display
Display of the APS value as voltage up to the first decimal place, ex)
3.2V;
(O) Current APS
Current APS voltage value display
Display of the APS value as voltage up to the first decimal place, ex)
3.2V;