![Navico MN000802A-G Installation Manual Download Page 60](http://html.mh-extra.com/html/navico/mn000802a-g/mn000802a-g_installation-manual_712252060.webp)
10.4
Setup the basics
•
After turning on the unit, press MENU|MENU, then use
↑
↓
to SYSTEM SETUP and press
ENT.
Communications Port selected from System Setup menu (left). Communications Port menu
(right).
•
From the System Setup menu, highlight COMMUNICATIONS PORT and press ENT.
•
Press
↓
to RADAR and press ENT, which will place an X in the radar checkbox. The Baud
Rate automatically will switch to 230400. Press EXIT repeatedly to return to the main page
display.
•
Press PAGES, then use
←
→
to select the radar tab.
•
Press
↓
to select RADAR ONLY, then press EXIT.
Radar only highlighted on Radar Pages menu (left). Radar menu with Radar Power selected
(right).
•
Press MENU, then use
↑
↓
to select RADAR POWER from the radar menu and press ENT. A
confirmation message will appear. Press
←
to select YES and press ENT. A warm-up
countdown will commence that will vary depending on the model of radar you have.
•
After the countdown is finished, the unit will enter STANDBY mode.
•
Access the Radar Setup menu to make sure your radar display is set to Heading Up and is
set to a Full Color scheme. Press MENU, select RADAR SETUP and press ENT.