9 Yellow
#24
1
10 White
(big)
#12
3
Shell Braid
shield
X
6.2
Run the 2 kW interconnection cable (NS003100/NS003101)
to the radar processor
Run the 2 kW interconnection cable (NS003100/NS003101) from the scanner to the radar
processor.
Push the round connector (A) of the 2 kW interconnection cable into the scanner connection on
the radar processor and tighten the locking nut.
The interconnection cable pin details are provided here for information, in case the connector
needs to be removed to feed the cable, or in case the cable needs to be shortened.
The front view of the 2 kW interconnection cable is shown above.
2 kW interconnection cable pin details
Pin
Color/Name
Signal name
AWG size
1 Green
(big)
Power
#12
2
Yellow (big)
Power GND
#12
3
Green (thin)
Pulse width
#24
4
Clear Coax signal
Video
#24
5
Drain wire for 4
Video GND
#24
6
Drain wire for 7
Trig GND
#24
7 Black
Coax
signal Trig/STC
#24
8
White
BZ Tune to scanner
#24
9
Yellow
Tune from scanner
#24
10
White (big)
No connection
#12
Shell Braid
shield