Connect power
The Broadband radar can operate on 12 or 24 V DC systems. The Broadband radar requires a
+V DC to be applied on the yellow power on wire in order to operate. This can be achieved in
one of three ways.
•
Common the red and yellow wire together. Radar will power on when power is applied
•
Use ignition or install a switch that will provide power to the yellow wire. (It is
recommended to use a 5 amp fuse or breaker). The radar will turn on when switch is
activated
•
Connect the yellow wire to external wake up of suitable display. Radar will turn on when
display is turned on
Before connecting power to the system:
•
Make sure the scanner has been installed and is secured.
•
Make sure the scanner interconnection cable is connected to the scanner.
•
If using the Radar Interface Box make sure all connections have been made to the
display.
For systems using a radar interface box
•
Connect the red wire to power positive 12 or 24 V DC. Use a 5 amp fuse or breaker.
•
Connect the yellow wire to power source that will turn on the system (see above).
•
Connect black to power negative.
For systems not using radar interface box (Lowrance HDS USA only)
•
Connect the red wire to power positive 12 or 24 V DC. Use a 5 Amp fuse.
•
Connect the yellow wire to power source that will turn on the system (see above).
•
Connect black to power negative.
20
|
2BWiring the radar system
Summary of Contents for BR24 - INSTALLATION REV D
Page 2: ...BLANK PAGE ...
Page 27: ...Radar interface box 4BDrawings 25 ...
Page 31: ...RF exposure compliance certificate 6BBR24 BroadBand radar scanner specifications 29 ...
Page 32: ...30 6BBR24 BroadBand radar scanner specifications ...
Page 33: ...6BBR24 BroadBand radar scanner specifications 31 ...
Page 34: ...BLANK PAGE ...
Page 36: ... MN000760D Navico Broadband Radar BR24 Installation Manual English MN000760D G 0191 ...