GB40
RI10
NETWORK
port
Adapter cable
000-0127-56
2 m (6 ft)
GB40 Ethernet cable
AA010079
0.6 m (2 ft)
8 port Ethernet linker or
(cross-over cable)
AA010009 (AA010084)
GB40
NETWORK port
Connects to GB40 system via Ethernet. Connect a GB40 Ethernet cable in between 8 port Ethernet linker
(or crossover cable) and supplied adapter cable. Use only GB40/8000i Ethernet cables. (Order separately)
Max Ethernet cable length from RI10 box to switch/display is 50 m.
GB40 SimNet Heading
SimNet heading sensor
FC40 or RC42
RI10
SimNet port
GB40 NavComputer
SimNet port
For MARPA functionality on GB40, heading information at 10 Hz needs to be sent to both the RI10 and the
GB40 NavComputer. Connect a SimNet drop cable from the Simnet backbone to the RI10 and connect to
the COMS port (SimNet connector). For connecting NMEA 0183 heading data to GB40 see 8000i NMEA
0183 Heading section below.
18
|
2BWiring the radar system