INTRODUCTION OF OPERATION PANEL
• 1'JY-IAYSSTART�AT
ACCaLDATION
O
POSITION
KNOii
,Uc,1101!
11'.+ENUOI.IDI-WdMEROOCUFIS:
• 1\,A,JAQCa..ERA.TlCNKNOEITO
O
• ,tOJUSTw.iNKNOBA0,,1.TO$
MAINKNO■
FAST
PU•Ga
/\IN
Acceleration
O
for
initial recovery down to 36 psi inlet pressure
Knob
€)
for fastest vapor recovery
Inlet valve is closed
Input valve is partially opened
Input valve is fully opened
01nV
Close
Recover
Fast
Purge
Input closed, and output is opened to allow the unit to remove most of the refrigerant inside
the recovery machine
Error Codes
• E1: T he pressure sensor is disconnected
• Fault 2: Input voltage is too low
• Fault 3: High input voltage
• Fault 4: Overcurrent protection
• Fault 5: Temperature sensor open
• Fault 6: Temperature sensor short circuit
• Fault 7: Temperature protector open
• Fault 8: Motor stalling
• Fault 9: Motor wire short circuit
• Fault 1 O: Motor wire short circuit
• Fault 11: PFC over electric current
• Fault 12: Motor temperature protection
� Mute Audible alerts and beeps are turned off
®
Fan This icon rotates while the machine is running. When the machine stops, the icon stops rotating.
Restart It will flash after an error has occurred and settled. Pressing START will resume activity
Empowering you to work smarter
NAVAC
PARTS DIAGRAM
1
Left Side Plate
15
Cylinder
2
Knob
16
Compressor
3
Control Panel
17
Motor
4
Digital Control Board
18
Inlet Tube
5
lnletTube
19
Outlet Tube
6
Condenser Inlet Tube
20
Cylinder Cover
7
Top Plate
21
Condenser Outlet Tube
8
Outlet Tube
22
Right Side Plate
9
Power Supply for Fan
23
Front Plate
10
Cover Board
24
Fans
11
Condenser
25
Cover Board
12
Rear Side Plate
26
Electric Reactor
13
Cylinder Cover
27
Motor Control
14
Valve
28
Base
06
07