Operator Manual Chapter3. For the beginning operator
© 2009
Nautilus Hyosung Inc.
All Rights Reserved. 3-13
Mode combination) by sequentially pressing those digits on the lock keypad. The
numbers will be displayed on the LCD as they are entered. When the combination
has been correctly entered, the LCD will read
OPr
, meaning "
OP
en
r
ight."
3. OPr
Retract Bolt
Turn the Dial to the right (CW) to retract the bolt
4. Open Door
5. Insert Change Key
Insert the change key into the change key socket on the back of the lock.
WARNING:
Do not close the door.
Leave the door open during this process until your are comfortable opening the lock
with the new combination.
6. Extend Bolt
Turn the Dial to the left (CCW) to extend the bolt.
7. Power Lock
Turn the dial to the left (CCW) until
(the Change Key symbol along with
Enter Combination) is displayed.
8.
Press #8
EcF
Press the “#” button followed by the “8” button. EcF (Enter current Factory
combination) will be displayed
9. EcF
Enter Current Shelved Mode Combination
EnF
Enter the current shelved mode combination, “EnF” (Enter new Factory combination)
will be displayed.
10. EnF
Enter New Combination
Cnf
Select and ente
r the new combination. “CnF” (confirm new Factory combination)
will be displayed
11. Cnf
Enter New Combination
POC
Enter new combination again to confirm. POC (Pull Out Change key) will be
displayed.
WARNING:
Record the new combination and store it in a secure place. If this combination is
lost or forgotten, there is no alternate way to open the lock.
12. POC
Remove Change Key
EOP
Remove the change key. EOP (End Operation) is displayed.