Chapter3. For the beginning operator Operator Manual
3-8
© 2009
Nautilus Hyosung Inc.
All Rights Reserved.
Optional Lock 1: Electronic Lock
► Opening Electronic Lock
1. The default combination for Electronic Lock is 1-2-3-4-5-6. Enter this sequence on
the electronic lock keypad. The lock will confirm a valid combination entry with a
double signal. Lock will signal three (3) times for invalid combination entry.
2. Turn the vault door handle counterclockwise. The vault door will open.
► Wrong Try Penalty
1. Entry of four (4) consecutive invalid combinations starts a five (5) minute delay
period.
▪ LED lashed red at ten (10) second intervals.
2. At the end of the delay period, two (2) more consecutive invalid combinations will
restart the additional five (5) minute delay period.
<Note!>
Entry will not respond to keystrokes during delay period.
► How to change the electronic lock combination
Always perform this operation with the door open.
1. Enter
0
-
0
-
0
-
0
-
0
-
0
, six (6) zeros, into the Electronic Lock keypad.
2. Enter in the old combination once.
3. Enter in the new combination twice. Combinations must be six digits in length.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1-3.
5. Test lock operation several times before closing the door.
<CAUTION>
When selecting a combination do not use birthday or other predictable data that could
give correlation between the user and combination.
<Note!>
The Electronic Lock will signal three (3) times if the new combination is invalid and the
old combination has been retained.
► Battery Low Warning
1. Repeated LED flashing and beeping during an opening indicates that the battery is
low and needs immediate replacement.
2. Uses one (1) 9-
Volt alkaline battery only. (Example: Duracell™ or Eveready™
alkaline batteries.) The replacement of batteries at least once annually is
recommended.
<Note!>
If battery is depleted and will not allow lock to open, follow instructions below.
Lock contains a non-volatile memory, even with batteries removed the lock will retain
all programming.