background image

3

IMPORTANT INSTRUCTIONS

Water-tight test of the housing (without 

camera inside) before usage is recom-

mended as well as any O-ring renewal 

and port change.

Use only Nauticam lubricant on silicone 

rubber O-ring.

Discontinue use immediately when there is 

a sign of leakage.

Do not expose the housing in direct 

sunlight for a prolonged period.

Prevent any sand or dust or water 

penetration inside the housing. Be 

extra careful when changing lens and 

inserting or removing the camera.

This product is not intended for use by 

children, or persons with reduced physical, 

sensory or mental capabilities, or lack of 

experience and knowledge, unless they 

are supervised and/or given instruction by 

a responsible person concerning use of 

the product to ensure that they can use it 

safely.

Do not seal the housing when travelling by 

air as this may lead to a pressure difference 

between the atmosphere and inside the 

housing.

Only the accesories speci

fi

 ed by 

Nauticam must be used. Third-party 

accessories may result in malfunctions 

or damage to the product.

Do not stretch any O-rings excessively. 

Only remove it using Nauticam O-ring 

remover.

Do not open the housing in wet or sandy 

environment. Protect the housing from 

moisture and debris in order to prevent 

malfunction or leakage.

1

3

5

7

9

11

12

4

6

8

10

2

Do not attempt to remove parts of the 

housing yourself. Repairs must be done 

at authorized service centers only.

The housing should be positioned on the a 

stable and safe surface on land.

Summary of Contents for NA-a1

Page 1: ...l Housing FF MIL Introduction 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Opening the housing Closing the housing 9 15 Preparation for Use Recommended Accessory PN 174...

Page 2: ...the included items listed below before using this product If some items are missing or damaged contact your local Nauticam dealer After purchase we suggest that you reuse all packaging materials for...

Page 3: ...are supervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead to...

Page 4: ...n Fn button AEL Image index button Display button Control wheel bottom Moisture alarm window Multi selector ISO button Control wheel left C4 Delete button 1 2 3 4 5 7 9 11 6 8 10 12 Rear View B 11 10...

Page 5: ...nsation lock Accessory mounting ball Port index mark Optical fiber cable connection Main switch C1 button AF illuminator Visible light sensor Focus mode lever Mode dial Exposure compensation dial Port...

Page 6: ...ES AND FUNCTIONS Back Side Views Zoom Focus dial Movie lever Sacrificial Zinc Anodes Playback lever AF ON Enlarge lever 1 4 Threaded tripod holes Shutter release lever Front dial 3 7 1 4 5 2 6 8 2 8 5...

Page 7: ...7 OPENING THE HOUSING depress housing unlock button turn housing lock outward lift up the back housing drawings as illustrations only 1 2 3...

Page 8: ...ate the main O ring make sure nothing is caught between front and back housing and that they are fully aligned before locking turn housing lock inward until you hear and feel it click into place housi...

Page 9: ...support the use of Sony A7RSIII camera in this housing and 17430UK Conversion kit is required untighten the camera tray clamp screws at the back of the camera tray then turn the clamps 1800 and tighen...

Page 10: ...e sure it is engaged with lens gear flip open the monitor for camera tray position 1 attach the camera tray by tightening the tray screw into the tripod socket of the camera drawings as illustrations...

Page 11: ...rt Mounting depress safety button and rotate anti clockwise lubricant the port O ring before mounting align index mark push port assembly straight in rotate locking lever clockwise to lock 1 2 3 drawi...

Page 12: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Page 13: ...LUE when it is working correctly test the alarm connect the wires with a dampened cotton bud the alarm will give a repeating beep and the mositure alarm window will flash RED press the battery down un...

Page 14: ...n to release pressure before unlocking port lock If using without vacuum valve please follow from step 2 unlock port lock and remove port assembly press the blue button to reset vacuum alarm before re...

Page 15: ...from steady green light to rapidly flashing yellow light that means there is a leakage Please check every O ring and then conduct the vacuum test again hand pump moisture alarm window accesory port on...

Page 16: ...not travel with camera inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommand cleaning and inspecting the main O ring each time after diving for an...

Page 17: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Page 18: ...unit 3 150mm relay lens 3 objective lenses 0 36x Wide Angle Conversion Port with Aluminium Float Collar incl N120 to N100 port adaptor In air Rating Port mount 25086 M24 adaptor for HDMI 2 0 cable inc...

Page 19: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Reviews: