![Nautel NX5 Installation Manual Download Page 27](http://html2.mh-extra.com/html/nautel/nx5/nx5_installation-manual_3571001027.webp)
NX5/NX3 INSTALLATION MANUAL
CONNECTING AC POWER
VERSION 3.1 2021-04-22
PAGE 2.4.5
Table 2.4.1: Three-phase primary winding tap nominal voltages (rms, phase-to-phase)
Figure 2.4.4: Transformer Line 1, 2, 3 Terminal Hardware Orientation
Ac Power Source Voltage
Tap
200 - 250 V ac
360 - 505 V ac
N/A
360
7
200
380
6
208
400
5
220
415
4
230
440
3
240
480
2
250
505
1
TRANSFORMER
TERMINAL
(LINE 1, 2, 3)
M6 NUT
(HMN05)
FLAT
WASHER
(HM44)
BRASS
WASHER
(HMW53)
TERMINAL
LUG
(HAM94)
M6 FLAT
WASHER
(HMW05)
M6 SPLIT
WASHER
(HMW35)
M6 HEX
SCREW
(HMSH36)
COMPLETED
LUG INSTALLATION
INSERT
WIRE HERE
TRANSFORMER
STRAP