8
If L coils are at limit, turn TX off and adjust coil taps as per ATU manual
Fig. 3
Fig. 4
Vane interrupts a light beam at
limits of travel.
L tuning
variometer.
R tuning variable matching
transformer.
L TUNING MAX or MIN LIMIT LEDs
should turn ON only at extremes of travel.
Otherwise limit sensor may be defective.
Do not proceed to optimize the R tuning until the L TUNING NORMAL LED is ON.
Limit Switch Assembly viewed from
motor end of end of shaft
Optimum Tune
Maximum L
Minimum L
ATU-HP: Tuning | Issue 1.0, Apr. 21, 2010
Page 3 of 4
Nautel Customer Support: 1.902.823.3900