D. Connecting the Boiler to an Existing Indoor Boiler
A plate heat exchanger is needed to transfer heat from the outdoor boiler to another indoor boiler or hydronic system
so that the two systems remain isolated from each other.
As shown in the above figure, the two systems are totally isolated from each other so that the existing hydronic
system remains undisturbed and functions exactly as before. All pumps and controls remain essentially the same on
the existing system. A second T-stat is needed to run the zone pumps independently of the indoor boiler burner. If a
30-plate unit or larger is used, a larger circulation pump on your boiler may be necessary for proper water flow.
Water that circulates through the boiler is never circulated through the home’s hydronic system or vice-versa.