10 Multipurpose Ozonator
User Manual
To set up automatic operation mode (Mode B)
ACTION
DIAGRAM
ACTUAL
PICTURE
DISPLAY
Plug product to the mains
Four dots
Press and buttons at the same time to
enter Mode B
OF:ON
Press to start setting. The last 2 digits
“ON” start flashing. This is to set the length
of operation time for the cycle.
Press to increase the operation time (5
minutes for every press, up to 30 minutes),
and press to decrease the operation
time (1 minute for every press, down to 0
minute.)
OF:MM
(MM means
operation
time to
be set in
minutes)
Press again to set the interval between
cycles. The first 2 digits “OF” start flashing.
Press to increase the interval time (0.5
hours for every press, up to 24 hours), and
press to decrease the interval time (0.1
hours for every press, down to 0 hours)
H.H:MM (H.H
for interval
time, MM for
operation
time )
Press again, and product should start
running. When MM (ON) counts down to
zero, product stops making ozone, and the
last two digits show the next operation time
(MM), and the H.H (OF) starts counting
down. When H.H (OF) counts down to zero,
the machine starts again. This is how cycles
are formed. Eg, if you wish your machine
to run for 15 minutes per day, the display
should read 24:15
H.H: MM
(H.H for
interval
time, MM for
operation
time)
If you wish to reset the operation and
interval time, just press again to reset
OF:ON
If you wish to enter Mode A, press and
buttons at the same time to quit Mode B
Four dots