5 TROUBLESHOOTING GUIDE
NOTE: Refer to WIRING CONNECTION DIAGRAM.
<TROUBLE>
<CHECK>
<REMEDY>
Hot air is not emitted at
→
Check continuity of the power cord.
→
Replace the power cord.
"II" or "I" position.
NO
↓
OK
Check continuity between (C) and (1) at "I" position of the main switch.
→
Replace the main switch.
Check continuity between (C) and (1), between (C) and (2) at "II" position
NO
of the main switch.
(probe "+" of tester at (C), "-" of tester at (2) only)
↓
OK
Check the resistance of the heater coil between red lead wire and black
→
Replace the heater block.
lead wire of the heater block.
NO
The value should be as follows:
220~240V
:approx. 53.5
Ω
110V
:approx. 12.3
Ω
↓
OK
Check the motor rotates when adding DC15V to the motor terminal.
→
Replace the motor.
NO
7
EH5235-A3
Summary of Contents for EH5235-A3
Page 3: ...3 EH5235 A3...