background image

  3 

About the Digital Microscope 

 
Your new digital microscope incorporates a built-in camera that uses data transmission made possible through a simple plug and 
play USB cable.  In order to achieve optimum results, it is important that you carefully read this manual before operating your 
microscope.  Instructions for software are located on Motic Images CD.   
 

UNPACKING 

 
1.  Your microscope is packed with the following components, all of which have been checked at the factory.  Carefully remove all 

components and check against this list.   

 

A.  Microscope, with WF10x eyepiece, four objective lenses, and 1.25 N.A. Abbe condenser. 
 
B.  Specimen holder 
 
C.  CD Motic Images software for PC and Mac 
 
D.  Calibration slide 
 
E.  USB cable (for connecting to computer) 
 
F.  Automatic switching recharger operates on 100 to 240 volts AC 50/60 Hz.  
 
G.  0.9mm “L” type hex key wrench (for replacing LED lamp). 
 
H.  Dustcover 

 
2. 

Retain styrofoam container in case microscope must be transported or returned to factory for any reason.

  If it 

becomes necessary to ship the microscope for any reason, repack it in the styrofoam container, and then pack the styrofoam 
in another corrugated shipping container for optimum protection.  Use of the styrofoam alone will not provide adequate 
protection in transit, and will void your warranty. 

 

DESCRIPTION OF COMPONENTS

 

 
1.  LED INDICATOR LIGHT:  Indicates if camera is on.  LED light becomes illuminated after software commands turn camera ON. 
 
2.  EYEPIECE  (ocular lens):  Lens closest to the eye, magnifies the primary image formed by the objective lens.  
  
3.  OBJECTIVE TURRET (nosepiece):  Revolving turret which holds objective lenses, permits changes of magnification by 

rotating different powered objective lenses into optical path. 

  
4.  OBJECTIVE LENS:  Lens closest to the object being viewed, forms first magnified image of the specimen. 
 
5.  SPECIMEN HOLDER:  Holds specimen slide. 
 
6.  STAGE:  Platform of the microscope where the specimen slide is placed. 
 
7.  CONDENSER:  A 1.25 N. A. Abbe condenser lens positioned under center of stage, condenses light rays from substage 

illumination and fills the back lens element of objective lens to improve image resolution. 

 
8.  IRIS DIAPHRAGM:  Attached to bottom of Abbe condenser, controls aperture of light by moving control lever left or right. 
 
9.  FILTER HOLDER:  Swing out filter holder with special neutral filter built in. 
 
10.  ON/OFF SWITCH: Main power switch for microscope LED Illuminator. 
 
11.  LIGHT HOUSE: Built-in substage LED illuminator provides constant, reliable pre-focused illumination equal to a 20-watt 

tungsten bulb.  Powered by 3 rechargeable AA nickel metal hydride batteries, no power outlet or electric cord are needed. 
 

12.  RHEOSTAT INTENSITY CONTROL:  Controls the intensity of the LED illuminator. 
13.  FOCUSING KNOBS:  Coarse focusing knobs (larger knobs) located on each side of arm, raise or lower stage to bring 

specimen image into focus.  Fine focus knobs (smaller knobs located just below coarse focusing knobs) permit more precise 
image adjustment. 

 
14.  MECHANICAL STAGE:  Permits precise mechanical manipulation of the specimen slide. 
 

Summary of Contents for DC-128

Page 1: ...W TO USE YOUR MICROSCOPE SERIAL NUMBERS 1 Microscope serial number This number etched on inside of small ledge immediately behind stage plate is the number under which your warranty is registered 2 Microscope Motic CD DM number This number found on a white sticker on the bottom of the microscope and on CD sleeve is used for logging on the Motic web site which gives you the ability to download free...

Page 2: ...ser 1 25 N A Base Specimen holder mechanical stage Fine focus knob USB output terminal 4 5 volt DC input 4 5 volt DC recharger Rack stop adjustment screw Knobs controlling X Y movement of mechanical stage Coarse focus knob Tension adjustment collar behind focus knob on left side Knurled locking screws for securing specimen holder to stage Rheostat intensity control knob Light On Off Switch ...

Page 3: ...amera ON 2 EYEPIECE ocular lens Lens closest to the eye magnifies the primary image formed by the objective lens 3 OBJECTIVE TURRET nosepiece Revolving turret which holds objective lenses permits changes of magnification by rotating different powered objective lenses into optical path 4 OBJECTIVE LENS Lens closest to the object being viewed forms first magnified image of the specimen 5 SPECIMEN HO...

Page 4: ...owered by 3 rechargeable AA nickel metal hydride batteries supplied These batteries may be recharged as required using the recharger supplied Each set of batteries may be recharged approximately 500 times before replacing and each charge will provide up to 50 hours of microscope operation The LED component bulb will last for up to 50 000 hours before replacement is required WARNING DO NOT USE regu...

Page 5: ...t b When using 4x and 10x objectives the special neutral filter must be in optical path c When using the higher power 40x and 100x objectives remove filter from optical path d To remove filter grasp filter holder knob and swing out filter holder G Changing magnification a Rotate revolving nosepiece to position 10x objective into optical path b This microscope has been parfocalled which allows chan...

Page 6: ...ith fine focus adjustment at mid range focus on standard slide until sharp image is obtained Rotate rack stop setscrew in clockwise direction until tight tighten locking nut B Coarse focus tension adjustment prevents the stage from drifting down from its own weight and causing the image to move out of focus The tension adjustment has been adjusted to appropriate tension at the factory However afte...

Page 7: ...acing LED element An LED bulb will last up to 50 000 hours so you don t have to do this exercise very often To open the illuminator field lens housing use hex wrench supplied with your microscope to loosen hex screw on side of lens housing Remove lens housing to expose LED bulb Remove bulb by grasping the plastic base of bulb and gently pulling straight up Insert new LED bulb replace lens housing ...

Page 8: ...or rechargeable LED microscope 951 Dustcover 16 tall x 13 heavy duty vinyl with stitched seams 975 001 Carrying case anodized aluminum fabric lining accessory pockets and Velcro straps keyed lock LIMITED LIFETIME WARRANTY Please see our website www nationaloptical com for complete warranty details and exclusions Revised 7 23 13 ...